Johnson Controls 13 SEER installation manual AC 1B, Single Stage Air Conditioner - PSC Air Handler

Models: 13 SEER

1 12
Download 12 pages 50.29 Kb
Page 8
Image 8
AC 1B

347337-UIM-A-0408

 

 

 

 

 

 

 

AC 1B

Single Stage Air Conditioner – PSC Air Handler

 

 

 

 

 

ID MODELS

 

 

 

 

 

AHP

 

 

 

 

 

 

 

SHP

 

 

 

 

THERMOSTAT

THERMOSTAT

 

MA

 

 

 

 

 

 

 

 

 

 

 

*BP11C50124

 

 

 

 

 

SINGLE STAGE

 

*BN11C01124

 

 

PSC

 

*BN11C00124

 

 

 

AIR

*DP11C40124

 

AIR HANDLER

 

 

 

 

CONDITIONER

 

*DN11C00124

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSC

1

SINGLE STAGE

 

 

 

AIR HANDLER CONTROL

 

AIR CONDITIONER

C

C

 

 

COM

 

C

24 – Volt Common

24 – Volt Common

 

24 – Volt Common

 

24 – Volt Common

Y

Y

 

 

Y/Y2

 

Y

 

Second or Full

 

Full Stage Compressor

Full Stage Compressor

 

 

Compressor Contactor

 

Stage Compressor

 

 

 

 

 

 

RH

RH

 

 

 

R

 

 

24 – Volt Hot

24 – Volt Hot

 

 

 

 

 

 

24 – Volt Hot

 

 

(Heat XFMR)

(Heat XFMR)

 

 

 

 

 

 

 

 

 

G

G

 

 

 

G

 

 

Fan

Fan

 

 

Fan

 

 

 

 

 

 

W2

 

 

 

 

 

Second Stage Heat

 

 

RC

RC

 

 

Y1

 

 

24 – Volt Hot

24 – Volt Hot

 

 

 

 

 

Single Stage Compressor

 

 

(Cool XFMR)

(Cool XFMR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

Reversing Valve

 

 

 

 

 

Energized in Cool

 

 

 

 

 

 

X/L

 

 

 

 

 

Malfunction Light

 

 

W

W

 

 

W1

 

 

Full Stage Heat

Full Stage Heat

 

First Stage Heat

 

 

 

External Humidistat

 

 

HUM

 

 

2

 

Humidity Switch

 

 

(Optional)

 

Open on Humidity Rise

 

 

 

 

 

 

 

Open on Humidity Rise

24VAC Humidifier

HUM OUT

 

 

 

 

(24 VAC out)

 

 

 

 

(Optional)

 

 

 

 

Humidifier

 

 

 

 

 

 

 

 

 

24VAC

EAC(24 VAC out)

 

 

 

 

Electronic Air Cleaner

 

 

Thermostat Installer Setup

Selection of GAS/ELEC

Electronic Air Cleaner

 

 

(Optional)

 

 

 

 

 

 

 

1-System Type-must be

switch on thermostat

 

 

 

 

 

 

set to 0

is not necessary

 

Move HUM STAT

 

 

Thermostat Installer Setup

 

 

 

 

 

 

jumper to “YES”

 

 

15-Compressor Protection

 

 

 

 

 

 

if humidistat is to be used.

 

 

must be set to 5

 

 

 

 

 

 

Refer to AH documentation

 

 

 

 

 

 

 

 

 

 

for W1 and W2 electric

 

 

 

 

 

heat staging options.

 

 

2

Part Number:

 

OtherPartPartNumbers:

21

 

 

SAP

=

Legacy

 

 

S1-2HU16700124

 

 

 

 

 

265902159480

=

031-0915667

 

 

 

 

 

 

 

FIGURE 10: Thermostat Chart - Single Stage AC with PSC Air Handler