AV-20N3 AV-20NMG3 AV-20NMG3B

Item

Measuring

Test point

instrument

 

 

 

Ad justment part

Description

Ad justment

Remote

 

7.SECAM

of SECAM

control unit

 

BL ADJUST

 

 

BL ACK

Signal

 

 

 

 

 

 

OFFSET

generator

 

 

 

 

 

 

 

KEY ASSIGNMENT OF REMOTE CONTROL UNIT

COLOUR

 

 

ON

 

 

1

2

3

COLOUR

 

 

OFF

 

 

4

5

6

7

8

9

[Method of adjustment using measuring instrument]

1.Input a SECAM full field colour bar signal.

2.Enter the SERVICE MENU.

3.Select 2. V/C from SERVICE MENU.

4.Select 7. SECAM BL ADJUST with /MENU key.

5.Set the initial setting value with the – or + MENU key.

6.Switch the key (colour OFF) and key (colour ON) on the remote control and make sure that there is no colour on the black and white screen.

7.If the black and white screen is not best with the initial setting value, make fine adjustment until you get the best black and white screen.

8.While watching the screen, adjust the value to be the same colour between ON & OFF by ten key on the remote control unit.

9.Press the DISPLAY key twice to return to the normal screen.

26

No. 52025

Page 26
Image 26
JVC AV-20NMG3/-A, AV-20N3/D, AV-20NMG3B Ad justment part Description Remote, Secam Control unit, BL Adjust, Bl Ack, Offset