Align them.
Usage precautions
2
1
How to attach the grip

EN

 

7 Do not throw the marine case into the water.

 

8 After use, wash off adequately with pure water as soon as

 

possible. If the marine case has been used in salt water, soaking

 

the marine case in pure water for a while is an effective way to

 

remove salt.

 

 

Be sure to operate all levers and buttons to wash off any salt in

 

the grooves. If any salt remains, it will dry out and crystallize.

3

This could result in water leakage.

9 After washing, wipe off any water with a dry cloth free of salt to

 

completely dry off the marine case. However, do not expose the

Fit them to

marine case to direct sunlight in order to dry it. This can cause

attachment holes.

discoloration and breakage of the marine case, and can speed

 

 

up deterioration of the O-ring.

 

0 Wipe the inside of the marine case with just a dry cloth.

 

Maintain the transparency of the front glass by wiping the inside

 

face with a silicon cloth or the like moistened with cleaner

 

agent.

 

 

! If the front glass is left dirty, it may cause fogging.

 

@ Remove the O-ring from the lid section and wipe off any salt,

1 Never use any of the following chemicals for cleaning, rust-

sand, and other foreign matter. In the same manner, wipe off

proofing, fog prevention, repair, or other purposes.

any adhering foreign matter from the groove into which the

1) Do not clean the marine case with alcohol, gasoline, paint

O-ring was fit and from the main unit of the marine case where

the O-ring contacted it. When removing the O-ring from the

thinner, or other volatile organic solvents, chemical cleaners

groove, avoid using sharp-tipped metal objects; instead use a

or similar agents. (Pure water or lukewarm water is adequate

round-tipped object, such as a hair pin, to avoid damaging the

for cleaning.)

O-ring when you remove it.

2) Do not use rust-proofing agents or the like on metal parts.

# Since the marine case is made of polycarbonate resin, handle it

(Stainless steel and aluminum are used for all metal parts, so

pure water is adequate for cleaning.)

carefully. In particular, it can be easily scratched by rocks, etc.

3) Do not use commercially-available anti-fogging agents.

at the shooting site and may be damaged if it is dropped or

(Always use the fogging agent that came with the marine

otherwise subject to shock. When going to the shooting site by

case.)

car, ship, train, or plane, avoid transporting the camcorder in

4) Do not use any silicon grease other than that specified for the

the marine case. If you take adequate handling precautions,

O-ring. (Always use the silicon grease that came with the

however, there should be no problem in transporting the

marine case.)

camcorder in the marine case for a short distance, for example

5) Do not use any adhesives for repairs, etc. (If any repairs are

from the target site to the diving site.

necessary, please consult the store of purchase.)

$ Avoid removing any parts other than those indicated in the

Direct or indirect use (vaporized chemicals) of any of the

user’s manual, altering the marine case, or using any parts other

above chemicals on the marine case can cause cracks when

than those specified. If any problems occur, please consult the

the marine case is placed under high pressure.

store of purchase.

 

2 Exercise caution, as this marine case is a completely airtight

% The appearance and specifications of this unit are subject to

structure. If it is left exposed to direct sunlight, or in a car, ship,

change without prior notice.

or on the beach, the internal temperature can climb extremely

 

 

high, which may cause the camcorder inside to stop working

 

 

properly.

 

 

3 Do not use the glass cleaner or cleaner for any purpose other

 

 

than cleaning the front glass.

 

 

4 If the camcorder is sealed inside the marine case in an area

 

 

where the humidity and temperature are high, diving will make

 

 

the humidity trapped inside the marine case cool down, causing

Main specifications

 

condensation to form and the glass surface to become fogged. It

 

is recommended that you insert the camcorder into the marine

 

 

 

case in an area where the humidity is low and the temperature

 

 

is close to that of the water where you will be diving.

Maximum pressure

: Water depth up to 30 meters

If a piece of aluminum foil is cut to approx. 50 cm2 and is

inserted into the glass part of the marine case, fog inside the

Power switch

: ON/OFF

marine case will adhere to the aluminum foil, as its heat

Recording start/stop

: START/STOP

conductivity is higher than that of glass. This is an effective way

Snapshot

: SNAPSHOT

to quickly reduce fog inside the marine case.

5 Do not open or close the case in areas where it may be

Zoom

: T/W

subjected to water spray or sand.

Main unit dimensions

 

6 If you must open the marine case at the diving site in order to

(W x H x D)

: 150 mm x 150 mm x 130 mm

replace the battery or tape, observe the precautions below.

Main unit weight

: Approx. 610 g

1) Select a location safe from water spray and sand.

Compatible model

: GR-DVP1, GR-DVP3

2) Completely wipe off any water between the main unit and

Accessories

: Maintenance kit (glass cleaner

the lid section of the main case and on the buckles. Thor-

oughly dry off any water remaining on the marine case with a

 

agent (for anti-fogging), cleaner

dry cloth.

 

agent (for removing dirt),

3) When removing the buckles and opening the lid section, be

 

silicon grease, silicon cloth,

careful that no water drips from your hair or body into the

 

anti-fogging silica gel, paper,

marine case.

 

 

cotton swabs, O-ring, strap,

4) In order to avoid touching the camcorder with hands that

 

 

grip)

have salt water on them, place a towel dampened with pure

 

 

 

water in a plastic bag beforehand and use it to wipe any salt

 

 

off your hands and fingers before touching the camcorder.