IMPORTANT PRODUCT SAFETY INSTRUCTIONS

Electrical energy can perform many useful functions. But improper use can result in potential electrical shock or fire hazards. This product has been engineered and manufactured to assure your personal safety. In order not to defeat the built-in safeguards, observe the following basic rules for its installation, use and servicing.

ATTENTION:

Follow and obey all warnings and instructions marked on your product and its operating instructions. For your safety, please read all the safety and operating instructions before you operate this product and keep this booklet for future reference.

INSTALLATION

1. Grounding or Polarization

(A)Your product may be equipped with a polarized alternating- current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature.

If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized plug.

(B)Your product may be equipped with a 3-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature.

If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug.

2. Power Sources

Operate your product only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. If your product is intended to operate from battery power, or other sources, refer to the operating instructions.

3. Overloading

Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk of fire or electric shock.

4. Power Cord Protection

Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against

3

5. Ventilation

Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these openings must not be blocked or covered.

Do not block the openings by placing the product on a bed, sofa, rug or other similar surface.

Do not place the product in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to.

6. Wall or Ceiling Mounting

The product should be mounted to a wall or ceiling only as recommended by the manufacturer.

ANTENNA INSTALLATION

INSTRUCTIONS

1. Outdoor Antenna Grounding

If an outside antenna or cable system is connected to the product, be sure the antenna or cable system is grounded so as to provide some protection against voltage surges and built-up static charges. Article 810 of the National Electrical Code, ANSI/NFPA 70, provides information with regard to proper grounding of the mast and supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding connectors, location of antenna discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.

2. Lightning

For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the antenna or cable system. This will prevent damage to the product due to lightning and power-line surges.

3. Power Lines

An outside antenna system should not be located in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outside antenna system, extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal.

EXAMPLE OF ANTENNA GROUNDING AS PER

NATIONAL ELECTRICAL CODE, ANSI/NFPA 70

ANTENNA

LEAD IN WIRE

GROUND CLAMP

them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product.

ELECTRIC SERVICE EQUIPMENT

ANTENNA DISCHARGE UNIT (NEC SECTION 810-20)

GROUNDING

CONDUCTORS

(NEC SECTION 810-21)

GROUND CLAMPS

POWER SERVICE GROUNDING ELECTRODE SYSTEM (NEC ART 250. PART H)

NEC – NATIONAL ELECTRICAL CODE

Page 3
Image 3
JVC HR-VP634U manual Important Product Safety Instructions

HR-VP634U specifications

The JVC HR-VP634U is a versatile VHS VCR that combines both performance and user-friendly features, making it a popular choice for enthusiasts of vintage media. Designed to offer high-quality playback and recording, this model stands out with its robust technological capabilities and practical functionality.

One of the key features of the HR-VP634U is its Super VHS capability, which supports enhanced video resolution and offers a sharper image quality compared to standard VHS recordings. This feature is particularly beneficial for users who may have a collection of Super VHS tapes, allowing them to experience their content in the best possible quality. The VCR also includes a built-in TBC (Time Base Corrector), which minimizes picture distortion and ensures smoother playback of older tapes, often plagued by video artifacts.

The JVC HR-VP634U comes equipped with several playback options, enabling users to enjoy various tape formats seamlessly. It includes a versatile set of connectivity options, including composite video inputs and outputs, an S-Video output for superior image quality, and an RF output for integrating with older televisions. This flexibility ensures compatibility with a range of equipment, making it easy to connect to modern setups or classic displays.

Recording capabilities are another highlight. The HR-VP634U allows for hassle-free programming through its on-screen display, making timer recording straightforward. This feature is perfect for capturing your favorite shows or events without needing to be present. Additionally, the VCR supports high-speed dubbing, enabling users to replicate their tapes efficiently.

The design of the JVC HR-VP634U is typical of VCRs from its era with a classic, sturdy chassis that is both durable and functional. The intuitive front panel layout provides easy access to controls, making it user-friendly for those who are familiar with VCR operations.

In conclusion, the JVC HR-VP634U is a reliable VCR that offers a blend of advanced technology and ease of use. Its Super VHS capability, TBC feature, diverse connectivity options, and robust recording functions make it a standout choice for preserving and enjoying your media collection. Whether you are a casual viewer or a dedicated collector, this model brings a nostalgic charm to video playback and recording.