JVC KA-HD250 Controls, Indicators and Connectors, Front Section, 1Viewfinder Holder, 2Lock Lever

Models: KA-HD250

1 15
Download 15 pages 37.13 Kb
Page 7
Image 7
Controls, Indicators and Connectors

e_ka250.book Page 7 Tuesday, September 5, 2006 4:10 PM

Controls, Indicators and Connectors

Front Section

1

2

3

f

e

d

 

4

c

0

 

b

9

5

a

8 7

6

1Viewfinder Holder

Use for mounting the VF-P400 4-inch Viewfinder.

2Lock Lever

Fastens the camera to this unit.

X See “Mounting the Camera” on page 10.

3[VF OUTPUT] round 20-pin

Connect the VF-P400 4-inch Viewfinder (sold separately). X See “Connecting the Viewfinder (VF-P400)” on page 11.

4[PROMPTER OUTPUT] Prompter Output Terminal (BNC)

The prompter video signal input to the [AUX] input termi- nal of the remote control unit is output from this terminal via the RM multi-pin connector. Composite signal is out- put. Video monitor is connected here.

5[VF] Viewfinder Cable

Connect to the VF terminal of GY-HD250.

6[BREAKER] Breaker Switch

Breaker switch trips and cuts off power if the power con- sumed is higher than the rated capacity. If the breaker switch trips, confirm that there are no abnormalities and that the power consumption does not exceed the rated wattage. If no abnormalities are detected, press the breaker switch before turning the power on again to put this unit in the operating status. If this unit still does not function properly, consult your JVC-authorized dealer.

7[VF OUTPUT] (Y/PB/PR/RGB) BNC×3

Component output terminal for viewfinder.Use when con- necting a Viewfinder other than VF-P400.

The HD/SD (from the GY-HD250) and composite video signal (from the RM-P210) can be switched. Use the GY- HD250 menu to set.

Recommended viewfinder:

DM-3106 (Astrodesign)

V-R70P-HAD (Marshall Electronics)

MEMO

When the viewfinder is connected to this terminal, the signal is not output correctly even if the viewfinder is con- nected to the 3 [VF OUTPUT] terminal.

When connected to the Y/PB/PR terminal of the monitor, the return video signal from the RM-P210 appears in black and white.

8[TALLY OUTPUT] Tally Signal Output Terminal (D-sub 9 pin)

Output tally signals. Use when connecting a VF other than VF-P400.

6

9

 

Signal

 

Signal

 

 

1

NC

6

NC

 

 

2

RM_PREVIEW

7

RM_TALLY

 

 

3

NC

8

NC

1

5

4

NC

9

NC

(Surface profile)

5

GND

 

 

 

 

 

 

9[TALLY INPUT]

 

 

 

 

Input tally signals.

 

 

 

 

9

6

 

Signal

 

Signal

 

 

1

NC

6

NC

 

 

2

TALLY_IN

7

NC

 

 

3

NC

8

NC

5

1

4

NC

9

NC

(Surface profile)

5

GND

 

 

 

 

 

 

0[RM] RM Multi-pin Connector (26 Pin)

Connect to Remote Control Unit RM-P210 by using the 26-pin camera cable. In addition, power is supplied to this unit and the camera from the remote control unit via this connector.

MEMO

Output Composite video signal and RGB component, Y/ PB/PR component and YC separate signals from the out- put terminal of RM-P210. Select the output signal using the “OUTPUT” item on the “SYSTEM” menu screen on the GY-HD250.

SD1 and HD signal cannot be output to the RM-P210.

aGenlock Output Cable (BNC)

Output cable for synchronization signals. Connect to the GENLOCK output terminal of GY-HD250.

bComposite Video Input Cable (RCA)

Input cable for composite video signals. Connect to the VIDEO output terminal of GY-HD250.

cDC Output Cable (XLR 4pin)

Connect to the DC INPUT terminal of GY-HD250.

dComponent Y/PB/PR Input Cable (BNC×3)

Input cable for component video Y/PB/PR signals. Connect to the each of the Y/PB/PR output terminals of GY-HD250.

e[CONTROL] Control Cable (Round 9 pin) Connect to the STUDIO terminal of GY-HD250.

f[REMOTE] Remote Cable (Round 6 pin) Connect to the REMOTE terminal of GY-HD250.

7

Page 7
Image 7
JVC KA-HD250 Controls, Indicators and Connectors, Front Section, 1Viewfinder Holder, 2Lock Lever, 3VF OUTPUT round 20-pin