ENGLISH

About Warning Indicators

The accumulated lamp time or warning mode of this unit is displayed by the indicators.

For information on indicator display during normal operation, see “Controls and Features” (pP10).

No.

 

Indicator

Content

 

 

 

LAMP

 

WARNING

 

 

 

 

 

 

 

 

1

 

 

 

Lamp replacement is near (pP40 f 42)

 

 

 

(When accumulated lamp time has exceeded 1900 hours)

 

Light on

 

b

 

 

 

2

 

Lamp has reached end of life (pP40 f 42)

 

 

 

 

 

 

(When accumulated lamp time has exceeded 2000 hours)

 

 

 

 

 

 

 

 

 

3

 

 

 

Lamp does not light up and unit is unable to project

 

 

 

 

 

4

Blinking

 

Light on

Lamp is turned off during projection

 

 

 

 

 

5

 

 

 

Lamp cover is removed

 

 

 

 

 

6

 

 

 

There is an error in the circuit operation

 

 

 

(Operation error in microcomputer circuit)

 

 

 

 

 

 

 

 

 

7

 

 

 

There is an error in the circuit operation

 

 

 

(Operation error in drive circuit)

 

 

 

 

 

 

 

 

 

8

b

 

Light on

Internal temperature is abnormally high

 

(Internal temperature error)

 

 

 

 

 

 

 

 

 

9

 

 

 

External temperature is high

 

 

 

(External temperature error)

 

 

 

 

 

 

 

 

 

10

 

 

 

Cooling fan has stopped

 

 

 

(Fan locked)

 

 

 

 

 

 

 

 

 

Actions to Be Taken for Warning Mode

When the unit enters into warning mode (No. 3 to 10), it will automatically stop projection and run the cooling fan for about 60 seconds.

After the cooling fan has stopped, pull out the power plug from the power outlet. Then, follow the procedures below.

No.

Check

Action

 

 

 

3

zCheck that an impact shock has not occurred during

 

 

operation.

 

4

Turn on the power again.

zCheck that the lamp unit and lamp cover are correctly

 

 

5

 

installed.

 

 

 

 

6

 

 

 

 

 

7

zCheck that nothing is blocking the air inlets.

Leave the unit until it cools down.

 

8

zCheck that the external temperature is normal.

After that, turn on the power again.

 

9

 

 

 

 

 

10

 

 

 

 

 

If the warning indication is displayed again, wait for the cooling fan to stop. Then pull out the power plug from the power outlet.

Call your authorized dealer for repair.

Started Getting

Preparation

Operation Basic

Settings

Troubleshooting

Others

39