8[HD/SD SDI OUTPUT] SDI signal output connectors (RM-HP250AU)

These are output connectors for HD/SD SDI signals. Use these to equipment with SDI input connectors (e.g., SDI switcher, monitor or VTR).

The specification varies depending on the model. RM-HP250AU : 3 outputs

8[HD/SD SDI INPUT/OUTPUT] SDI signal input and output connectors (RM-HP250DE)

These are HD/SD SDI signal input/output connectors. SDI signal that is input will be output from the [HD/SD SDI OUTPUT] connectors.

The specification varies depending on the model. RM-HP250DE : 1 input, 2 outputs

NOTE

Transferred signals cannot be output via the camera cable from the HD/SD SDI output connector on RM- HP250DE. Signals will be output in the same format as the input signals to HD/SD SDI input connector.

9[REMOTE] Connection connector of Remote Control Panel

This connector connects to the remote control panel and controls the camera.

When connected, remote control panel operations will take priority over operations from RM-HP250 (3: FILE, 4: PROCESS, 5: OPERATION).

Introduction

0[CAMERA CABLE] connector (26-pin)

Connect the optionally available camera cables to the camera.

Camera Cable (Optional)

The VC-P110series camera cables that can be used to connect a camera to the RM-HP250are available in four lengths as listed below.

VC-P110 : 5 meters

VC-P112 : 20 meters

VC-P113 : 50 meters

VC-P114 : 100 meters

A menu setup is required according to the cables in use.

REF. : “Camera Cable Length Setup” on page 12.

NOTE

If it is required to extent the cable, use the KA-280 extension connector.

The total cable length should not exceed 100 meters.

7