Specify pinout, distinction between make/break (m1 or b1) and the time (millisecond) when alarm output is specified.
Segments are indicated by /. The time is 0 or from 100 to 5000. When the time is 0, alarm output does not come back
to previous state.
Setting Example /api/param?application.event(1).action=pinout/m1/1500
B&W mode is available for VN-V26. Specify true_daynight/bw, true_daynight/color, true_daynight/autoH,
true_daynight/autoM or true_daynight/autoL when B&W mode is specified.
Setting Example
/api/param?application.event(1).action=camera.image.true_daynight/bw
Alarm action of event number 6 is periodic FTP. Event 1 to 5 can not be set to periodic FTP. Parameters of FTP can
be set by another API, application.ftp.
Allowed users admin, operator
Getting Alarm Filter Setting from VN-V25/26
Format /api/param?application.event(Number).filter(WeekOfDay).status
Example When Getting Setting of Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).status
Example of Response application.event(1).filter(sunday).status=off&200 OK
Interpretation Acquire filter setting of the alarm action for the specified alarm number. Up to 5 alarm actions can
be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between
the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. When the filter is
enabled, on will be returned. When the filter is disabled, off will be returned.
Allowed users admin, operator
Setting Alarm Filter for VN-V25/26
Format /api/param?application.event(Number).filter(WeekOfDay).status=data
Example When setting Sunday filter of Alarm No. 1
/api/param?application.event(1).filter(sunday).status=on
Example of Response
application.event(1).filter(sunday).status&202
Accepted(application.event(1).status=restart)
Interpretation Set filter setting of the alarm action for the specified alarm number. Up to 5 alarm actions can be
specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the
35