Interpretation Acquire the unit of interval for accessing the NTP server. "min", "hour" or "day" is returned.
Allowed users admin, operator, user
Setting Access Interval Unit of SNTP for VN-V25/26
Format /api/param?network.ntp.unit=data
Example /api/param?network.ntp.unit=day
Example of Response
network.ntp.unit&202 Accepted(network.ntp.status=restart)
Interpretation Change the unit of interval for accessing the NTP server. Specify "min", "hour" or "day". To
validate the change, use "network.ntp.status=restart" API.
Allowed users admin, operator
Getting Time from VN-V25/26
Format /api/param?system.date
Example of Response system.date=20050614171537&200 OK
Interpretation Acquire the time from the built-in clock of VN-V25/26. Time is arranged in the order of year,
month, day, hour, minute and second. Year is denoted in a 4-digit decimal number, and month, day, hour, minute and
second are denoted in 2-digit decimal numbers.
Allowed users admin, operator, user
Setting Time for VN-V25/26
Format /api/param?system.date=data
Example /api/param?system.date=20050614171537
Example of Response system.date&200 OK
Interpretation Change the time of the built-in clock in VN-V25/26. Specify in the order of year, month, day, hour,
minute and second. Specify year in a 4-digit decimal number, and month, day, hour, minute and second in 2-digit
decimal numbers.
Allowed user admin
Getting Timezone from VN-V25/26
Format /api/param?system.timezone
Example of Response system.timezone=Pacific&200 OK
Interpretation Acquire the timezone from VN-V25/26. Character strings in the following table will be returned.
Timezone Character String Description
GMT-12 Timezone that is 12 hours earlier than the Greenwich Mean Time.
65