Power Connection

Electricity can be supplied to this product either by connecting to the AC 24 V power supply or using the PoE (A Page 18).

When power is supplied to this product, the [STATUS] indicator at the side lights up. The indicator lights up in orange color during startup, and switches to green color after startup is complete.

Memo:

You can select not to light up the [STATUS] indicator when the unit is running. (A Page 75)

Note:

Make sure to select only one mode of electrical supply. Connecting the power cord and the LAN cable for the PoE at the same time may result in failure or malfunction of the camera.

Be sure to use an AC 24 V supply that is isolated from the primary power supply circuit. Using a variable voltage power supply will cause the camera and system to malfunction or breakdown.

Connecting to the AC 24 V power supply

Connect this product to the AC 24 V power supply when the PoE is not used.

Note:

Make sure to select only one mode of electrical supply. Connecting the power cord and the LAN cable for the PoE at the same time may result in failure or malfunction of the camera.

The unit is to be powered by an AC 24 V power supply.

The AC 24 V power supply should conform to the following: Class 2 only (For USA), Isolated power supply only (For Europe and others).

To Power

Supply

1

2

 

G 2 1

2 1

 

 

AC24V

INPUT

ALARM

OUTPUT

CLASS2 ONLY FOR USA ISOLATEDPOWER ONLY FOREUROPE AND OTHER

 

 

OUT

PoE

 

AUDIO

IN/OUT

 

MONITOR

 

 

 

 

 

 

 

10BASE-T/

 

 

SEE INSTRUCTION MANUAL

 

100BASE-TX

 

 

CAUTION: NEVER USE PoE AND AC 24V AT THE SAME TIME

 

DO NOT CONNECT TO THE TELEPHONE NETWORK

PUSH

MONITOR OUT

PAL OFF NTSC

RESET

STATUS

IRIS

[STATUS] Indicator

Power cord

To prevent misconnection and detachment of cords, use a lug plate to connect the cord to the terminal.

When a two-core VVF (vinyl insulated vinyl sheath cable) is used, the connection distance is as follows.

Conductor Diameter

R1.0mm

R1.6 mm

R2.0mm

(AWG No.)

(18) and

(14) and

(12) and

 

above

above

above

 

 

 

 

Maximum Extension

140 m

360 m

570 m

 

 

 

 

Warning

The rated power of this product is AC 24 V, 50 Hz/60 Hz. Make sure to use it with the correct voltage.

Use an AC 24 V supply that is isolated from the primary power supply.

Supplying a power beyond the rated value may result in failures, smoke or fire. When the camera breaks down, turn off the power and contact our service center immediately. When a power beyond the rated value is supplied, the internal components may be damaged even if no abnormality is found on the appearance and operation of the camera. Please contact our service center immediately for servicing (charged separately).

Memo:

After DHCP timeout, all IP addresses of VN-X35U are set to 192.168.0.2 by default. When the power of multiple cameras within the same LAN environment are turned on at the same time, the IP address of the cameras overlap, thus preventing proper access. As such, make sure to turn on the power of the cameras one by one.

17