JVC VR-609 manual Setting values of TK-C676 or TK-C655, Rx+

Models: VR-609

1 102
Download 102 pages 24.6 Kb
Page 27
Image 27

JVC VR-609

● Connection of RS-485 Control signal cable

VR-609

 

 

RS-485 Connector

Camera1 Connector

+

RX+

C

 

-

RX-

D

 

GND

Camera2 Connector

 

 

 

 

 

 

 

RX+

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When you install in a place with many noises,

 

 

 

 

 

RX-

D

 

 

 

 

 

 

please use a twisted-pair cable with a shield.

 

 

 

 

 

 

 

 

 

 

 

 

A shield cable should be connected to a GND

 

 

 

 

 

 

 

 

 

 

terminal.

 

 

 

 

 

 

 

 

 

 

Camera9 Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX+

RX-

C

D

3.3.2 Setting values of TK-C676 or TK-C655

 

 

 

 

Item

Value

 

 

Switch 4

ON

 

 

Switch 5

ON

 

 

Switch 8

Terminal equipment is set to ON.

Other equipments are set to OFF.

 

 

 

ID

Install ID value independently.

 

 

 

 

The functions can be used by this equipment are PAN/TILTE/ZOOM/FOCUS/AUTO FOCUS. (A setup of a home position, a preset position, etc. cannot be performed) In addition, in order to perform a home position setup and a camera image setup in advance, it is possible to use and set-up by remote controler of RM-P2580 grade. Please read the Instructions of RM-P2580.

About setting values of VR-609, please refer to 5.1.2 Camera details and 5.1.3 Pan/Tilt Model Select.

For information of other model, consult your nearest JVC dealer.

!Please connect the Pan/Tilt camera of the same protocol (Camera Setup -> Pan/Tilt Model Select -> Select Model).