Kalorik USK ICBM 30155 manual Troubleshooting, Problem, Possible Cause, Suggested Solutions

Models: USK ICBM 30155 USK ICBM 30116

1 12
Download 12 pages 63.87 Kb
Page 7
Image 7
TROUBLESHOOTING

￿

TROUBLESHOOTING

Problem

Possible Cause

Suggested Solutions

“Add water“ indicator

There is no water

Fill the water tank with water,

light is on, a long beep

 

wait 3 minutes and press the

sounds

 

start button to restart.

“Ice Full“ indicator

The ice tank full

Empty ice basket completely

light is on, a beep

capacity is reached

or partially, wait 3 minutes and

sounds

 

press the start button to restart.

My Ice melts

The compressor has

Restart the compressor by

 

stopped automatically.

pressing on start after the “Ice

 

 

Full” or “Add Water” have

 

 

been lit (see above).

 

 

Nevertheless, operation will

 

 

restart automatically once the

 

 

temperature in the cavity will

 

 

be above 40°F

Pilot lights do not turn

Blown fuse/ No power

Check the power socket /

on

 

Have the fuse replaced by a

 

 

competent electrician. Please

 

 

use fuse value AC 250V, 3.15A,

 

 

5 x 20 only

The Ice made falls like

The water temperature

Stop the machine and reset

a single block, with a

in the water storage

the ice making cycle. Restart

lot of cubes sticking

box or ambient is too

the machine after turning it off.

together.

low

 

Conditions for ice

Refrigerant might be

Call 1-888-KALORIK for service

making cycles are right

leaking / sealed system

or email through

but no ice is made.

is

www.kalorik.com

 

blocked

 

The lights of ice full and

Water tray is blocked

Unplug the appliance.

deficient come on in

by ice cube

Clean the evaporator.

the same time.

 

Plug the appliance back in

 

 

and press the ”START” button.

 

 

The appliance will restart

 

 

automatically after 2 minutes.

The ice cube maker is

Water pipe is clogged

Please pull out the cap of the

jammed, or the water

by limescale or other

water pipe, then let the water

does not flow uniformly

particles

through the pipe in order to

in the evaporator

 

clean it and wash the clog

 

 

away, then replace the cap.

 

 

Resume operation.

 

7

USK ICBM 30116/30155 - 090716

Page 7
Image 7
Kalorik USK ICBM 30155, USK ICBM 30116 manual Troubleshooting, Problem, Possible Cause, Suggested Solutions