CHANGING YOUR FILTER (CONT’D.)
To change the filter:
Step 1 |
|
| Step 2 |
|
| Step 3 |
|
| Step 4 |
|
|
|
|
|
|
|
|
|
|
|
|
Uses replacement filter |
| Turn off and unplug | Remove the water tank. | Remove and discard | |||||
WF2. |
| your humidifier. |
|
| old filter. | ||||
|
|
|
|
|
|
|
|
|
|
Step 5 |
|
| Step 6 |
| Step 7 |
|
| Step 8 |
|
|
|
|
|
|
|
|
|
|
|
Soak new filter in cool | DO NOT wring filter. | Insert new filter into | Replace the water tank. |
water. |
| unit by gently folding |
|
|
| and inserting into filter |
|
|
| slot. |
|
CHANGING THE UV BULB
The UV bulb will operate for an average output of 2,000 - 3,000 hours. When the change UV bulb indicator light illuminates on the control ring on front of the unit it is time to change your UV bulb. To purchase a replacement UV bulb contact
Step 1 | Step 2 | Step 3 | Step 4 |
CHANGING THE UV BULB (CONT’D.)
NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site. Bulb and bulb housing are not intended for use with any other product or purpose.
Lamp contains mercury. Manage in accordance with disposal laws.
See www.lamprecycle.org or call
CLEANING
Cleaning involves two steps, SCALE REMOVAL and DISINFECTING. Be sure to perform these in the proper order to avoid harmful chemical interactions.
NOTE: REMOVE FILTER BEFORE CLEANING.
Failure to remove filter during cleaning will destroy the filter
SCALE REMOVAL
Step 1 |
|
| Step 2 |
|
| Step 3 |
|
| Step 4 |
|
|
|
|
|
|
|
|
|
|
|
|
Turn off and unplug | Remove and empty | Remove filter and | Rinse thoroughly with |
your humidifier. | water tank. | using undiluted vinegar, | water to remove |
|
| wipe base and tank | scale. * |
|
| thoroughly. |
|
DISINFECTING
Step 1
Step 2
Step 3 | Step 4 |
1 g la |
|
Turn off and unplug your humidifier.
Step 5
Remove and empty the | Remove the filter, | Turn base over, | |
water tank. | empty the base of | locate door, and | |
|
| water and dry. * | remove screws with |
|
|
| Philips screwdriver. |
|
| * Warning: carefully empty water | |
Step 6 |
| ||
|
| from base using the directional arrows | |
|
| imprinted on the unit to be certain no | |
|
| water enters it. Completely dry base | |
|
| before changing UV Bulb. | |
|
|
|
|
Turn off and unplug your humidifier.
Remove and empty water tank.
Remove filter and fill | Wipe base with the |
water tank with 1 tsp | same solution. |
of bleach and 1 gallon |
|
of cool water. Do not |
|
overfill water tank. |
|
Unscrew old bulb and | Replace door and |
replace with new one. | screws and reassemble |
| unit. |