Wiring

Wiring

You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric company requirements when you install this wiring.

If you are not familiar with electric codes and practices, or if you have any doubt, even the slightest doubt, in your ability to connect the wiring to this water heater, obtain the service of a competent electrician. Contact your Sears salesperson to arrange for a professional electrician.

WIRING DIAGRAMS

C-2

C-2

STANDARD WIRING FOR

STANDARD WIRING FOR

SINGLE ELEMENT 240 VOLT

SINGLE ELEMENT 120 VOLT

FIGURE 11.

WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This water heater is equipped for one type voltage only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT use this water heater with any voltage other than the one shown on the model rating plate. Failure to use the correct voltage can cause problems which can result in death, serious bodily injury, or property damage. If you have any questions or doubts consult your electric company.

If wiring from your fuse box or circuit breaker box was aluminum for your old water heater, replace it with copper wire. If you wish to reuse the existing aluminum wire, have the connection at the water heater made by a competent electrician. Contact your Sears salesperson to arrange for a professional electrician.

1.Provide a way to easily shut off the electric power when working on the water heater. This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch.

2.Install and connect a circuit directly from the main fuse or circuit breaker box. This circuit must be the right size and have its own fuse or circuit breaker. Refer to the chart in the “Product Specifications” section for the correct size wire and fuse or circuit breaker.

3.If metal conduit is used for the grounding conductor:

A. The grounding electrode conductor shall be of copper, aluminum, or copperclad aluminum. The material shall be of one continuous length without a splice or joint.

B. Rigid metal conduit, intermediate metal conduit, or electrical metallic tubing may be used for the grounding means if conduit or tubing is terminated in fittings approved for grounding.

C.Flexible metal conduit or flexible metallic tubing shall be permitted for grounding if all the following conditions are met:

The length in any ground return path does not exceed 6 feet.

The circuit conductors contained therein are protected by overcurrent devices rated at 20 amperes or less.

The conduit or tubing is terminated in fittings approved for grounding.

For complete grounding details and all allowable exceptions, refer to the current edition of the NEC - National Electrical Code NFPA 70.

4.A standard 1/2” conduit opening has been made in the water heater junction box for the conduit connection.

5.Use wire nuts and connect the power supply wiring to the wires inside the water heater’s junction box.

6.The water heater must be electrically “grounded” by the installer. A green ground screw has been provided on the water heater’s junction box. Connect ground wire to this location.

7.Replace the wiring junction cover using the screw provided.

WIRING CONNECTIONS