PRODUCT SPECIFICATIONS

HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND ELECTRICAL WORK ARE REQUIRED.

Examine the location to ensure the water heater complies with the “Facts to Consider About the Location” section in this manual.

5.For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during

an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

6.Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

PRODUCT SPECIFICATIONS

 

TANK

DIMENSIONS

 

ELEMENT

 

MAXIMUM FUSE

MODEL

CAPACITY

IN INCHES (mm)

RECOVERY RATE

WATTAGE

MINIMUM

OR CIRCUIT

IN GALLONS

 

 

GALS.PER HOUR

 

 

WIRE SIZE*

BREAKER

NUMBER

(LITERS)

DIA.

HEIGHT

@900F Rise

120 Volt

240 Volt

(GAUGE)

SIZE (AMPS)

153.316040

6 (22.7)

14.250” (362)

15.375” (391)

7.5

1650

----

12

20

153.316050

10 (37.8)

16” (406)

18.25” (464)

7.5

1650

----

12

20

153.316060

19 (71.9)

18” (457)

24.9” (632)

7.5

1650

----

12

20

153.316070

19.9 (75.3)

16” (406)

31.62” (803)

7.5

1650

----

12

20

153.316331

30 (113.6)

22” (559)

30” (762)

7.5

1650

----

12

20

153.326060

19 (71.9)

18” (457)

24.9” (632)

9.1

----

2000

14

15

153.326070

19.9 (75.3)

16” (406)

31.62” (803)

9.1

----

2000

14

15

153.326331

30 (113.6)

22” (559)

30” (762)

9.1

----

2000

14

15

* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.

Some compact models have labeled optional plumbing connections see below.

MODEL

STANDARD

STANDARD

STANDARD

MODEL HAS OPTIONAL

MODEL HAS OPTIONAL

NUMBER

SIDE COLD INLET

SIDE HOT INLET

SIDE T&P

TOP COLD INLET

TOP HOT OUTLET OR T&P

153.316040

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

 

 

 

 

 

 

153.316050

YES

YES

YES

NO

YES, PLUGGED

153.316060

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

153.316070

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

153.316331

YES

YES

YES

NO

NO

153.326060

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

 

 

 

 

 

 

153.326070

YES

YES

YES

YES, PLUGGED

YES, PLUGGED

153.326331

YES

YES

YES

NO

NO

Page 5
Image 5
Kenmore 153.31604 owner manual Product Specifications