HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND ELECTRICAL WORK ARE REQUIRED.
Examine the location to ensure the water heater complies with the “Facts to Consider About the Location” section in this manual.
5.For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during
an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
6.Massachusetts Code requires this water heater to be installed in accordance with Massachusetts
PRODUCT SPECIFICATIONS
| TANK | DIMENSIONS |
| ELEMENT |
| MAXIMUM FUSE | ||
MODEL | CAPACITY | IN INCHES (mm) | RECOVERY RATE | WATTAGE | MINIMUM | OR CIRCUIT | ||
IN GALLONS |
|
| GALS.PER HOUR |
|
| WIRE SIZE* | BREAKER | |
NUMBER | (LITERS) | DIA. | HEIGHT | @900F Rise | 120 Volt | 240 Volt | (GAUGE) | SIZE (AMPS) |
153.316040 | 6 (22.7) | 14.250” (362) | 15.375” (391) | 7.5 | 1650 | 12 | 20 | |
153.316050 | 10 (37.8) | 16” (406) | 18.25” (464) | 7.5 | 1650 | 12 | 20 | |
153.316060 | 19 (71.9) | 18” (457) | 24.9” (632) | 7.5 | 1650 | 12 | 20 | |
153.316070 | 19.9 (75.3) | 16” (406) | 31.62” (803) | 7.5 | 1650 | 12 | 20 | |
153.316331 | 30 (113.6) | 22” (559) | 30” (762) | 7.5 | 1650 | 12 | 20 | |
153.326060 | 19 (71.9) | 18” (457) | 24.9” (632) | 9.1 | 2000 | 14 | 15 | |
153.326070 | 19.9 (75.3) | 16” (406) | 31.62” (803) | 9.1 | 2000 | 14 | 15 | |
153.326331 | 30 (113.6) | 22” (559) | 30” (762) | 9.1 | 2000 | 14 | 15 |
* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
Some compact models have labeled optional plumbing connections see below.
MODEL | STANDARD | STANDARD | STANDARD | MODEL HAS OPTIONAL | MODEL HAS OPTIONAL |
NUMBER | SIDE COLD INLET | SIDE HOT INLET | SIDE T&P | TOP COLD INLET | TOP HOT OUTLET OR T&P |
153.316040 | YES | YES | YES | YES, PLUGGED | YES, PLUGGED |
|
|
|
|
|
|
153.316050 | YES | YES | YES | NO | YES, PLUGGED |
153.316060 | YES | YES | YES | YES, PLUGGED | YES, PLUGGED |
153.316070 | YES | YES | YES | YES, PLUGGED | YES, PLUGGED |
153.316331 | YES | YES | YES | NO | NO |
153.326060 | YES | YES | YES | YES, PLUGGED | YES, PLUGGED |
|
|
|
|
|
|
153.326070 | YES | YES | YES | YES, PLUGGED | YES, PLUGGED |
153.326331 | YES | YES | YES | NO | NO |