Installation Instructions (cont'd)
Installation Checklist
HOT
•Whether or not the element conversion is made, the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the loweraccess panel.
•Is the fiase or circuit breaker size correct as shown in the chart in the "Product Specifications" section?
•Are the wires from the circuit breaker or fuse service to the
water heater's 'unction box on the correct wire size (gauge) as shown in the chart in the "Product Specifications" section?
•Is the new
and piped to an adequate drain? See
•Is the water heater completely filled with water? See "Filling
the Water Heater" instructions in the "Installation Instructions sect on.
•Wdl a water leak damage anything? See "Facts to Consider About the Location" section.
•Are the cold and hot water lines connected to the water heater
correctly?gee "Water Piping" instructions in the "Installation Instructions"section•
•Is there adequate clearance for maintenance around the water heater?
•Do you r_eed to call your electric company to check your wiring?
COLD
TEMPERATURE- PRESSURE
RELIEF VALVE
PIPE
(Do not cap
or plug)
6" AIR GAP
MODEL RATING PLATE
15