Installation Instructions (cont'd)

Temperature-Pressure

Relief Valve

_,WARNING

At the time of manufacture this water heater was provided with a combination temperature-pressuresrelief valve certi- fied by a nationally recognized testing laboratory that main- tains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the current edition of ANSI Z21.22, CSA 4.4 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and

Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4 by a nationally recognized testing laboratory that maintains periodic inspection of pro- duction of listed equipment or materials.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 Ibsdsq. in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3412 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI

Z21.22 CSA 4.4 and ASME, may require a valve model dif- ferent from the one furnished with the water heater.

Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the facto- ry furnished valve.

For safe operation of the water heater, the relief valve must not be removed from it'sdesignated opening or plugged. The temperature-pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches above, or at any distance below the structural floor. Be cer- tain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in

size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and

reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6" air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other restriction.

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the dis- charge pipe.

Must terminate at an adequate drain.

Mustnothaveanyvalvebotweenthereliefvalveandtank.

_,WARNING

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (I) no one is in front of or around the outlet

of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.

If after manually operating the valve, it fails to complete- ly reset and continues to release water, immediately, close the cold water inlet to the water heater, follow the

draining instructions, and replace the temperature-pres- sure relief valve with a new one.

TEMPERATURE-PRESSURE

RELIEF VALVE

DISCHARGE

PIPE

(Do not cap or plug)

6 ,f

AIR GAP

FLOOR DRAIN

9

Page 9
Image 9
Kenmore 153.318031, 153.318131 owner manual Temperature-Pressure Relief Valve

153.318131, 153.318031 specifications

The Kenmore 153.318031 and 153.318131 are contemporary models of dishwashers that combine sophistication with functionality. Known for their efficiency and innovative features, these machines are designed to enhance kitchen experience while delivering exceptional cleaning results.

One of the main features of the Kenmore 153.318031 and 153.318131 is their impressive washing performance. Equipped with powerful jets and a multi-stage washing system, these dishwashers ensure that every dish, from heavily soiled pots to delicate glassware, is cleaned thoroughly. The advanced spray technology allows water to reach all corners of the dishwasher, ensuring that no food particles are left behind.

Energy efficiency is a noteworthy characteristic of these models. Both dishwashers are designed to operate with minimal electricity and water usage, making them a sustainable choice for environmentally conscious consumers. They are compliant with ENERGY STARĀ® ratings, underscoring their commitment to reducing energy consumption without compromising on performance.

Another striking feature of the Kenmore 153.318031 and 153.318131 is their spacious interior. With adjustable racks and multiple loading options, users can easily customize the arrangement to fit various dish sizes and shapes. The flexibility offered by these models allows for maximum use of interior space, making them ideal for families or those who entertain frequently.

The control panels are user-friendly, often featuring intuitive touch controls and a digital display that offers complete cycle information at a glance. With multiple wash cycles and settings to choose from, users can select the optimal washing program for their specific needs, including options for heavy, normal, quick, and eco-friendly cycles.

Noise reduction technology is another hallmark of these dishwashers. Engineered to operate quietly, the Kenmore 153.318031 and 153.318131 ensure that users can run them at any time without interrupting the household's daily activities or conversations.

In terms of design, both models boast a sleek and modern aesthetic, available in several finishes to match various kitchen decors. Their solid construction not only lends them an attractive appearance but also ensures durability and longevity.

Overall, the Kenmore 153.318031 and 153.318131 are designed to meet the diverse needs of today's households. Combining practicality with cutting-edge technology, they deliver on the promise of cleanliness and efficiency, making them an excellent investment for any kitchen.