Installation Instructions (cont'd)
2. The | convertible element | is located | behind | the lower access | 5. Remove the | screws from terminal 2 of the element, and move |
panel | of the water heater. | Remove | the two | screws securing | the looped | end of the wire aside. |
the access panel, and remove panel. |
|
|
|
|
3. Remove the insulation block to expose the opening.
4.Lower Element: Lift out the tab as shown to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.
Lift cut tab to until term hal cover from
6.The buss bar is labeled 5500 W. Place the buss bar over termi- nals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3.
7.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.
:hecrnostat.
TERMINAL COVER
CLIPPED TO THER-
PLASTIC TABS ON ?BOTH SIDES OF TERM1NAL COVER HOLD IT IN
pLACE.
THERMOSTAT
BRACKET
8.Tighten terminals 2 and 3 to ensure proper electrical connection.
AWARNING]
Failure to tighten terminal screws can causea fire whichI can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE. | / |
LOWER THERMOSTAT_]