Removing the Burner Door Assembly

1.Turn off the gas to the water heater at the manual gas shut-off valve (Figure 3).

2.Turn the gas control knob on the combination gas control valve/thermostat clockwise to the “OFF” position (Figure 1). NOTE: Depress the dial stop on Robertshaw valve before turning the gas control knob. See Lighting Instructions on the water heater.

3.Remove the outer door.

4.Remove the two screws securing the burner door assembly to the combustion chamber. (Figure 24).

GAS VALVE/

THERMOSTAT

PIEZO

THERMOCOUPLE IGNITER BUTTON

MANIFOLD

TUBE

VIEWPORT

PILOT

TUBE

BURNER

DOOR

DOOR

TWO PIECE WIRE

SCREW (2)

CONNECTOR

FIGURE 24.

5.Disconnect the thermocouple (right-hand thread), pilot tube, the igniter wire from the igniter button, and manifold tube at the thermostat.

(Figure 25).

6.Grasp the manifold tube and push down slightly to free the manifold tube, pilot tube, and thermocouple.

7.Carefully remove the burner door assembly from the combustion chamber. Be sure not to damage internal parts.

ROBERTSHAW GAS VALVE

PILOT TUBE

THERMOCOUPLE

MANIFOLD TUBE

FIGURE 25.

Ultra Low NOx Natural Gas Burner

Check the burner to see if it is dirty or clogged. The burner may be cleaned with soft paint brush (Figure 26). Do not use a wire brush or any tool that may damage the burner screen. Important: Do not use the burner if the burner screen is damaged. NOTE: Damage may be rips or holes in the burner screen. Discoloration is normal.

PILOT ASSEMBLY

BURNER

USE BRUSH ON THIS SURFACE

FIGURE 26.

Replacing the Pilot Assembly

1.Follow the instructions in “Removing the Burner Door Assembly” section to remove the assembly.

2.Remove the retainer clip securing the two piece wire connector to the burner door assembly. (Note the orientation of the retainer clip). Insert the tip of a large flat head screwdriver between the clip and the top of the two piece wire connector. Carefully rotate the screwdriver to raise the clip. It may be necessary to remove the connector one side at a time. (See Figure 27.)

3.Locate where the thermocouple connects to the rear of the pilot assembly, and pull the thermocouple tip from the rear of the pilot assembly.

4.Remove the nut securing the pilot assembly to the burner and keep it for reuse later.

5.Use a 1/2” open end wrench, to loosen the nut securing the pilot tube to the pilot. To prevent any bending use a pair of pliers to steady the pilot bracket.

6.Remove the old pilot assembly (including the igniter wire) from the burner door assembly.

7.Insert the pilot tube into the new pilot assembly. Important: The new pilot assembly comes with an orifice. This orifice must be installed when replacing the pilot assembly.

IMPORTANT: Do not operate this water heater without the orifice in place.

8.Use a 1/2” open end wrench, to tighten the nut securing the pilot tube to the pilot. To prevent any bending use a pair of pliers to steady the pilot bracket.

9.Use the nut removed in a previous step to secure the new pilot assembly to the burner.

10.Insert the igniter wire through the burner door and reconnect the thermocouple to the pilot assembly. See “Replacing the Thermocouple” section.

11.Reinstall the two piece wire connector. NOTE: The pilot tube must be at the top followed by the igniter wire then the thermocouple.

12.Follow the instructions in “Replacing the Burner Door Assembly” section to reinstall the assembly.

21

Page 21
Image 21
Kenmore 153.33096 Removing the Burner Door Assembly, Ultra Low NOx Natural Gas Burner, Replacing the Pilot Assembly

153.33097, 153.33096 specifications

Kenmore has long been a trusted name in home appliances, and their washer models 153.33096 and 153.33097 are no exception. These machines stand out for their modern features, advanced technology, and user-friendly characteristics that cater to the needs of today’s households.

One of the main features of both models is their efficient cleaning performance. The machines are equipped with a powerful wash system that ensures thorough dirt and stain removal, even from heavily soiled fabrics. The dual-action agitator in each model enhances the washing process by allowing optimal movement of laundry, resulting in cleaner clothes in less time.

In terms of capacity, the Kenmore 153.33096 and 153.33097 offer a generous wash drum size, accommodating large loads. This is particularly convenient for families or individuals who do laundry less frequently. The higher capacity not only saves time between cycles but also reduces water and energy consumption, making these washers environmentally friendly options.

The models feature various wash cycles and temperature settings to suit different fabric types and soiling levels. Users can select from options like delicate, heavy-duty, and quick wash cycles, providing flexibility for various laundry needs. This versatility is further enhanced by the inclusion of a digital display and intuitive controls, making it easy to customize each wash.

Another key characteristic of the 153.33096 and 153.33097 is the incorporation of advanced technology. The machines utilize a smart sensor system that detects load sizes and automatically adjusts water levels accordingly. This feature not only conserves water but also ensures optimal cleaning performance for every load.

Noise reduction technology is also a significant advantage of these Kenmore models. Using advanced sound-dampening materials, they operate quietly, making them a desirable choice for any household, especially in open-plan living spaces.

In summary, the Kenmore 153.33096 and 153.33097 washers are exemplary products that combine performance, efficiency, and user-friendly design. With their robust features, advanced technologies, and thoughtful characteristics, they deliver an exceptional laundry experience that meets the demands of modern life. Whether you're dealing with everyday laundry or specialized items, these Kenmore models offer tailored solutions to ensure outstanding cleanliness and convenience.