LookatthetopofthewaterheaterThecoldwaterinletis.

marked"COLD"Puttwoorthreeturnsofteflontapearound. thethreadedendofthethreaded-to-sweatcouplingand aroundbothendsofthe3/4"NPTthreadednippleUsing. flexibleconnectors,connectthecoldwaterpipetothecold waterinletofthewaterheater.

NOTE: This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss

can be accomplished by insulating the hot water lines from the water heater.

INSTALLATION COMPLETED USING INSTALLATION KIT

 

 

 

FLEXIBLE

 

 

 

 

 

WATER

 

 

NOT WATER

 

CONNECTORS

 

 

 

 

 

COLD WATER

 

 

 

 

 

OUTLET

 

 

 

INLET

 

 

t

t

VALVE

 

 

 

SHUTOFF

 

THREADED

TO

THREADED TO

 

SWEAT

COUPLING

SWEAT

COUPLING

 

HEAT TRAP

WITH

_

"41""""""-

314"THREADED

SECONDARY

 

COUPLING/HEAT

TRAP

ANODE

 

 

 

 

3/4"THREADED

_

 

 

 

 

 

 

DRAFTHOOD

 

 

 

 

 

 

TEMPERATURE-

 

 

 

_PRESSURE

 

 

 

 

 

RELIEF

VALVE

DISCHARGE PIPE

(Do not cap or plug)

FLOORDRAIN

FIGURE 15.

T & P Valve and Pipe Insulation

Remove insulation for T & P valve and pipe connections from carton.

PIPE

INSULATION FLUE PIPE

T&P)

RGURE 15A.

Fit pipe insulation over the incoming cold water line and the hot

water line. Make sure that the insulation is against the top cover of the heater.

Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve.

Secure all insulation using tape.

Temperature-Pressure Relief Valve

Explosion Hazard

Temperature-pressure relief valve

/must comply with ANSI Z21.22 and ASME code.

• Properly sized temperature- pressure relief valve must be installed in opening provided.

Can result in overheating and excessive tank pressure.

Can cause serious injury or death.

This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer.

The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of

listed equipment of materials as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water

Supply Systems, ANSI Z21.22 and the code requirements of ASME.

If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035 kPa) and a discharge capacity not less than the water heater input rate as shown on the model rating plate.

For safe operation of the water heater, the relief valve must not be removed from its designated opening nor plugged.

The temperature-pressure relief valve must be installed directly into the fitting of the water heater designed for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor, see Figure 16. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size

under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must

be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

13

Page 13
Image 13
Kenmore 153.331413 HA, 153.331514 HA Temperature-Pressure Relief Valve, Insulation Flue Pipe, Floordrain, Rgure 15A

153.331413 HA, 153.331514 HA, 153.331543 specifications

The Kenmore model 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units are popular options for consumers seeking reliable and efficient cooling solutions. These models are renowned for their innovative features and robust performance, catering to a range of residential needs.

One of the standout characteristics of the Kenmore 153 series is its energy efficiency. Designed with advanced technology, these air conditioners are equipped with high SEER ratings. This means they consume less energy while providing optimal cooling, ultimately leading to reduced utility bills. Additionally, they utilize environmentally-friendly refrigerants, aligning with modern regulations for eco-friendly appliances.

Another notable feature is the adjustable cooling settings. Users can easily customize their comfort levels with multiple fan speeds and temperature settings. This flexibility allows for energy savings and tailored cooling according to the specific needs of different rooms or times of day.

The Kenmore 153.331514 HA model stands out as a heavy-duty option, suitable for larger spaces, boasting a higher BTU rating for enhanced cooling power. Its smart technology integration facilitates remote control access through smartphones, allowing users to adjust settings even when they are away from home.

The Kenmore 153.331413 HA, meanwhile, is an excellent choice for medium-sized areas, providing efficient cooling without overpowering smaller spaces. Its user-friendly digital display and programmable timers enhance convenience, ensuring that the air conditioning operates only when necessary.

Lastly, the Kenmore 153.331543 model features a sleek and modern design that blends seamlessly with home decor. Its quiet operation ensures that it does not disrupt daily activities, making it ideal for living rooms and bedrooms.

The durability of these air conditioning units is another key aspect. Built with high-quality materials, they promise longevity and continuous performance, reducing the need for frequent repairs or replacements.

In summary, the Kenmore 153.331514 HA, 153.331413 HA, and 153.331543 air conditioning units offer a combination of efficiency, flexibility, and durability. With features tailored to enhance user experience and comfort, they stand out as top choices for those seeking effective home cooling solutions.