Operational Conditions (Continued)

Leakage Checkpoints

F_URE27.

Read and understand instruction manual and safety messages

before installing, operating or servicing this water heater.

Failure to follow instructions and

safety messages could result in death or serious injury

Instruction Manual must remain with water heater

Read this manual first. Then before checking the water heater make sure the gas supply has been turned "OFF", and never turn the gas "ON" before the tank is completely full of water.

Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" gas to the water heater, see Figure 27.

A. Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact the gas utility.

B. *Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C. *The anode rod fitting may be leaking.

D. Small amounts of water from temperature-pressure relief valve may be due to thermal expansion or high water pressure in your area.

E. *The temperature-pressure relief valve may be leaking at the tank fitting.

R Water from a drain valve may be due to the valve being slightly opened.

G. *The drain valve may be leaking at the tank fitting.

H. Combustion products contain water vapor which can condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

Water in the water heater bottom or on the floor may be from

condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

*To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow "Draining" instructions in the Periodic Maintenance section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow Filling the Water Heater instructions in the Installing the New Water Heater section.

25

Page 25
Image 25
Kenmore 153.333345, 153.333545, 153.333415 HA, 153.333445, 153.333315 HA Operational Conditions Leakage Checkpoints, FURE27

153.333315 HA, 153.333445, 153.333415 HA, 153.333545, 153.333345 specifications

The Kenmore 153.333345, 153.333545, 153.333445, 153.333315 HA, and 153.333415 HA air conditioning units represent a diversified range of solutions for both residential and commercial climate control needs. These models are specifically designed to meet the varying requirements of different environments, making them excellent choices for effectively managing indoor temperatures.

One of the main features of these Kenmore models is their advanced energy efficiency. Each unit is equipped with Energy Star certification, ensuring that they consume less electricity compared to standard models. This not only helps consumers save on energy bills but also contributes to environmental sustainability by reducing greenhouse gas emissions.

The cooling capacity of these units is tailored to fit spaces of various sizes. With BTU ratings that range across the different models, users can find an appropriate solution whether they require cooling for a small room or a more expansive area. Additionally, the inclusion of variable speed compressors allows for precise temperature control and improved humidity management, providing enhanced comfort without excessive energy expenditure.

Technologically, these models incorporate modern smart features that make user interaction seamless. Many of the Kenmore units can be controlled via smartphone apps and are compatible with smart home systems. This connectivity allows users to adjust settings, set schedules, and even monitor energy usage remotely.

The design of the Kenmore air conditioners emphasizes ease of installation and maintenance. Their lightweight construction permits simpler setups, while detachable filters ensure that air quality remains high by allowing for easy cleaning and replacement. Moreover, the units feature robust build quality, designed to withstand the rigors of daily use over many years.

In terms of noise levels, Kenmore has prioritized quiet operation. These air conditioners are engineered to operate at lower decibel levels, meaning that they can be used in bedrooms or quiet office spaces without causing disturbances.

In summary, the Kenmore 153.333345, 153.333545, 153.333445, 153.333315 HA, and 153.333415 HA air conditioning units present a blend of energy efficiency, advanced technology, ease of use, and reliability. These features make them excellent choices for anyone looking to optimize indoor comfort while minimizing energy impact.