Kenmore 153.33443, 153.33453 TROUBLESHOOTING GUIDE Continued, 0ROBLEMM, #Ause, 3OLUTION

Models: 153.33453 153.33443

1 32
Download 32 pages 25.09 Kb
Page 29
Image 29
TROUBLESHOOTING GUIDE (Continued)

TROUBLESHOOTING GUIDE (Continued)

These guidelines should be used by a qualifi ed service agent. Call Sears Service at 1-800-4-MY-HOME®(1-800-469-4663)

for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.

0ROBLEMM

#AUSE

3OLUTION

 

Improperly sealed, hot or cold supply

 

 

connection, relief valve, drain valve, or

Tighten threaded connections.

WATER LEAKS

thermostat threads.

 

Leakage from other appliances or water

Inspect other appliances near water

 

 

lines.

heater.

 

Condensation of flue products.

Refer to CONDENSATION.

 

Thermal expansion in closed water system.

Install thermal expansion tank (DO NOT

LEAKING T&P VALVE

plug T&P valve).

 

Improperly seated valve.

Check relief valve for proper operation

 

 

(DO NOT plug T&P valve).

 

 

SMELLY ODORS

High sulfate or mineral content in water

Drain and flush heater thoroughly, then

supply.

refill.

 

Bacteria in water supply.

Chlorinate or aerate water supply.

 

Gas knob dial not positioned correctly.

Refer to LIGHTING INSTRUCTIONS.

 

Main gas supply off.

Turn on main gas shutoff valve.

 

Igniter tip more than 1/8” from pilot hood.

Adjust ignitor tip.

 

Thermopile malfunction.

Replace pilot assembly.

 

Thermopile TCO malfunction.

Replace pilot assembly.

PILOT WILL NOT LIGHT

Melted insulation on ignitor wire or shorting

Contact Sears Service to determine

of ignitor wire.

cause.

 

High ambient room temperature.

Contact Sears Service to determine

 

cause.

 

 

 

Wire disconnected from piezo igniter.

Reconnect wire connector to piezo igniter.

 

Broken electrode or electrical wire.

Replace pilot assembly.

 

Piezo Igniter generator fails to operate or

Replace electronic control module.

 

malfunctions.

 

 

 

Thermopile TCO malfunction.

Replace pilot assembly.

 

High ambient room temperature.

Contact Sears Service to determine

 

cause.

BURNER WILL NOT STAY LIT

 

Dirty or clogged Intake Screen.

Clean and reinstall Air Intake Screen.

 

Flame arrestor openings blocked.

Contact Sears Service to determine

 

cause.

 

 

 

Defective Gas Control.

Replace Gas Control.

 

Dirty pilot burner.

Clean pilot assembly.

PILOT OUTAGE

Dirty or clogged Air Intake Screen.

Clean and reinstall Air Intake Screen.

Thermopile malfunction.

Replace pilot assembly.

 

Thermopile TCO malfunction.

Replace pilot assembly.

 

Defective Gas Control.

Replace Gas Control.

 

Heater not lit or thermostat not on.

Refer to LIGHTING INSTRUCTIONS.

 

Thermostat set too low.

Refer to TEMPERATURE REGULATION.

 

Heater undersized.

Reduce hot water use.

NOT ENOUGH HOT WATER

Low gas pressure.

Contact your gas supplier.

Incoming water is unusually cold.

Allow more time for your heater to re-heat.

 

 

Leaking hot water pipes or fixtures.

Have plumber check and repair leaks.

 

High temperature limit switch activated.

Contact Sears Service to determine

 

cause.

 

 

WATER TOO HOT

Thermostat set too high.

Refer to TEMPERATURE REGULATION.

WATER HEATER SOUNDS

Condensation dripping on burner.

Refer to CONDENSATION.

 

Sediment or calcium in bottom or heater

Clean sediment from tank. Refer to

SIZZLING – RUMBLING

DRAINING instructions in Maintenance

tank.

 

section of manual.

 

 

SOOTING

Improper combustion.

No adjustment available. Contact Sears

Service to determine cause.

 

 

 

Lack of supply air.

Contact Sears Service to determine

VENT GAS ODORS

Improperly installed vent piping.

Downdraft.

cause.

 

 

Poor Combustion.

 

29

Page 29
Image 29
Kenmore 153.33443, 153.33453 owner manual TROUBLESHOOTING GUIDE Continued, 0ROBLEMM, #Ause, 3OLUTION