Problem

LED Status

Cause

Solution

 

OFF

Electronic control module off or pilot

Check for power to heater.

 

Check wiring harness for proper connection.

 

assembly off.

 

 

Check for line voltage at harness connectors.

 

 

 

 

1 flash *

Electronic control module is powered

Normal operation. No action required.

 

and pilot lit.

 

 

 

 

 

 

Inspect thermopile connection to gas control

 

 

 

valve.

 

2 flashes *

Thermopile voltage low.

Inspect flame coverage on thermopile.

 

Check inlet gas pressure.

 

 

 

Run open circuit thermopile output test and

 

 

 

change thermopile if output is low.

 

 

 

Replace pilot assembly.

 

 

 

Restart gas control valve.

 

3 flashes *

Gas control valve or tank sensor

If main burner turns on after restart, replace

 

tank sensor.

 

failure.

 

 

If main burner does not turn on after restart,

 

 

 

 

 

 

replace gas control valve.

 

4 flashes *

Gas control valve overheat failure

Replace gas control valve assembly and

 

(pilot off or burner off).

electric control module.

 

 

 

 

 

Verify tank sensor is connected to electric

 

 

 

control module.

 

5 flashes *

Lower tank sensor failure (pilot on

Verify tank sensor is connected to the heater

 

tank.

 

and burner off).

 

 

Run tank sensor calibration check.

 

 

 

 

 

 

Replace tank sensor and electric control

 

 

 

module.

 

 

 

Verify tank sensor is connected to electric

 

 

 

control module.

GAS

6 flashes *

Upper tank sensor failure (pilot on

Verify tank sensor is connected to the heater

tank.

VALVE

and burner off).

 

Run tank sensor calibration check.

 

 

 

 

 

 

Replace tank sensor and electric control

 

 

 

module.

 

7 flashes *

Electric control module failure (pilot

Replace electric control module.

 

on or off and burner off).

 

 

 

 

8 flashes *

Gas control valve failure (pilot off and

Replace gas control valve assembly and

 

burner off).

electronic control module.

 

 

 

6 second solid light

Pilot stays lit only when control knob

Overheat failure. Replace gas control valve

 

followed by 4 flashes *

is depressed in PILOT position.

assembly and electronic module.

 

6 second solid light

Pilot stays lit only when control knob

Electronic control module failure. Replace

 

followed by 7 flashes *

is depressed in PILOT position.

module.

 

6 second solid light

Pilot stays lit only when control knob

Gas control valve failure. Replace gas control

 

valve assembly and electronic control

 

followed by 8 flashes *

is depressed in PILOT position.

 

module.

 

 

 

 

6 second solid light with

Pilot stays lit only when control knob

Overheat failure and electronic control

 

combinations of 4 + 7

module failure. Replace gas control valve

 

is depressed in PILOT position.

 

flashes *

assembly and electronic module.

 

 

 

6 second solid light with

Pilot stays lit only when control knob

Overheat failure and gas control valve failure.

 

combinations of 4+ 8

Replace gas control valve assembly and

 

is depressed in PILOT position.

 

flashes *

electric module.

 

 

 

6 second solid light with

Pilot stays lit only when control knob

Electric control module failure and gas

 

combinations of 7 + 8

control valve failure. Replace gas control

 

is depressed in PILOT position.

 

flashes *

valve assembly and electronic module.

 

 

 

6 second solid light with

Pilot stays lit only when control knob

Overheat failure, electronic control module

 

failure, and gas control valve failure. Replace

 

combinations of 4 + 7 + 8

 

is depressed in PILOT position.

gas control valve assembly and electronic

 

flashes *

 

 

module.

 

 

 

 

Continuous solid light

System shutdown/safety interlock.

Wait until light goes out to restart gas control

 

valve.

 

 

 

* Flashes are approximately 1/10 second in duration with approximately three seconds between groups of flashes.