Service and Adjustment (cont'd)
L.P. Gas Control Valve & Burner
Assembly Replacement
Information
AWARNING
PROPANE (L.P.) GAS CONTROL VALVE AN BURNER ASSEMBLY REPLACEMENT INFORMATION.
For Propane (L.P.) Gas Models Only."
Your water heater is equipped with a Propane
for the following fittings and their connections.
The connection between the manifold and the gas control valve (A to B) are left hand threads.
The connection between the main burner orifice and the manifold (C to D) are left hand threads.
For ordering these replacement parts, please refer to the "Repair Parts" section of this manual.
Draining
The water heater should be drained if being shut down during
freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
Turn the Has control knob to the "OFF" position. CLOSE me cold water inlet valve to the water heater.
•OPEN a nearby hot water faucet and leave open to allow for draining.
•Connect a hose to the drain valve and terminate to an ade- quate drain.
•OPEN the water heater drain valve to allow for tank draining. NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be lefl open with hose connected allowing water to terminate to an adequate drain.
•Close theorain valve.
Follow instructions in the "Filling The Water Heater" section.
Follow the lighting instructions in the "Lighting" section to restart the water heater.
Temperature-Pressure Relief
Valve Operation
The
RELIEF VALVE
DISCHARGE PIPE
Failure to install and maintain a new properly listed tempera-
AWARNING
If the
expansion. Your water heater may have a check valve installed in the water line or a water meter with a check
valve. Consultthe SearsService Center for further informa- tion. Do not plugthe
AWARNING
When checkingthe
If after manually operating the valve, it fails to completely reset and continuesto release water, immediately closethe cold water inlet to the water heater, follow the draining
instructions, and replace the
26