Installation Instructions

Installation Checklist

BEFORE LIGHTING THE PILOT:

Check the gas lines for leaks.

a, Use a soapy water solution. DO NOT test for gas leaks usinga match or open flame•

b.Brush the soapy water solution on all gas pipes, joints and fittings•

c.Check for bubbling soap. This means you have a leak.

(cont'd)

VENT PIPE TO

OUTDOORS

OR CHIMNEY

SHUTOFF VALVE

Turn "OFF" gas andmake the necessary repairs.

d.Recheck for leaks.

e.Rinse off soapy solution and wipe dry.

ls the new temperature-pressure relief valve properly installed

and piped to an adequate drain? See "Temperature-Pressure Relief Valve" section•

Are the cold and hot water lines connected to the water

heater correctly? See "Water Piping" instructions in the "Installation Instructions" section.

Is the water heater completely filled with water? See "Filling" instructions in the "Installation Instructions" section•

Will a water leak damage anything? See the "Facts to Consider About the Location" section.

Is there proper clearance between the water heater and any- thing that might catch fire. See the Facts to Consider About the Location" section.

Do you have adequate ventilation so that the water heater

_

See

*c

....

Air and Ventdatlon

.

wdl operate properly.

 

Combustion

 

in the "Installation Instructions" section,

Is the draft hood vent piping properly secured? See "Venting" instructions in the "Installation Instructions" section.

Is there proper clearance between the vent pipe and anything

that might catch on fire? See "Venting" instructions in the "Installation Instructions" section•

HOT

COLD

UNION

 

 

 

DRAFT HOOD

TEHPERATURE-

 

 

 

 

 

 

 

/

PRESSURE

 

 

GAS

SUPPLY

RELIEF VALVE

 

 

 

 

 

 

--

DISCHARGE PIPE

 

 

 

 

(Do not cap or plug)

SHUTOFF

VALVE

 

 

 

 

 

[]

 

 

 

TEE

-_J

 

 

DRIP

LEG -----_

 

(Sediment

trap)

 

 

 

 

CAP

 

 

DRAIN

VALVE

6" AIR GAP

 

 

 

FLOOR DRAIN

Is the vent pipe properly sloped and does the vent terminate outdoors? See "Venting" instructions in the "Installation Instructions" section.

SUITABLE FOR WATER (POTABLE)

HEATING ONLY

Do you need to call your gas company to check the gas pipe and its hookup?

B_

 

QALS.n

 

 

UAXI_ HyO_TA_

 

 

GAS pnESSU_

_ W C

150

I

 

I

I

psi

 

wc

wc

AUTOMATIC STORAGE WATER HEATER

AUTOMATIC CIRCULATING TANK WATER HEATER

MODEL RATING PLATE

17

Page 17
Image 17
Kenmore 153.337002, 153.337072 owner manual Installation Checklist, Before Lighting the Pilot, Model Rating Plate

153.337002, 153.337072 specifications

The Kenmore 153.337072 and 153.337002 represent a duo of high-efficiency window air conditioning units that have become popular choices for consumers seeking effective cooling solutions. Engineered with modern technology, these models promise to deliver optimal performance while maintaining energy efficiency.

One of the standout features of the Kenmore 153.337072 is its dual cooling and heating functionality. This versatility allows it to not only cool spaces during the hot summer months but also provide warmth during the chillier seasons. With a cooling capacity of 7,000 BTUs, it is suitable for rooms up to 350 square feet, making it ideal for bedrooms or small living areas. On the other hand, the 153.337002, while also a cooling unit, focuses solely on cooling performance, boasting a similar BTU capacity tailored for energy-efficient cooling.

Both models incorporate advanced energy-saving technologies. They are equipped with Energy Efficiency Ratio (EER) ratings that exceed the minimum standards set by energy regulatory bodies. This means consumers can enjoy a comfortable indoor climate without incurring high electricity bills. With features like programmable timers and sleep modes, users can manage cooling more effectively, adjusting temperature settings to minimize energy consumption.

In terms of user convenience, both units come with user-friendly remote controls, allowing easy adjustments from anywhere in the room. The digital control panel is intuitive, featuring clear LCD displays for monitoring settings. They also include multiple fan speeds and cooling modes to cater to individual preferences, ensuring a personalized experience.

Maintenance is simplified with the inclusion of washable and reusable air filters, which enhance indoor air quality by reducing dust and allergens. A filter replacement indicator alerts users when a cleaning is required, promoting optimal performance and hygiene.

In conclusion, the Kenmore 153.337072 and 153.337002 embody a blend of efficiency, user convenience, and advanced cooling technology. Whether you are looking for a unit that provides both heating and cooling or one focused solely on cooling, these models offer reliable solutions to keep indoor spaces comfortable year-round. Their commitment to energy efficiency not only benefits consumers economically but also aligns with environmentally conscious practices, making them a noteworthy choice in the air conditioning market.