Installation Instructions (cont'd)

Typical Installation

HOT WATER

VACUUM RELIEF REQUIRED BY SOME CODES

(REFER TO LOCAL CODES)

OUTLET

 

(

TO CHIMNEY

OR GAS

VENT

HOT

SPACE HEATER

SPACE HEATER

TEMPERED

WATER OUTLET

MIXING VALVE

 

GAS

-- TEMPERATURE-PRESSURE

SUPPLY

 

RELIEF VALVE

--DISCHARGE PIPE (Do not cap or plug)

-DRAIN VALVE

DRAIN PAN

I TO SUITABLE DRAIN

This appliance has been design certified as complying with American National Standards for water heaters and is considered suitable for:.

Water (Potable) Heating: All models are "considered suitable for water (potable) heating."

Water (Potable) Heating and Space Heating: Certain models are "considered suitable for water (potable) heating and space heating." Refer to the model and rating plate of the water heater.

AWARNING

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- perature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/men- tally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addi- tion to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available

at plumbing supply or hardware stores. Follow manufac- turers instructions for installation of the valves. Before

changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual.

_WARNING

This water heater shall not be connected to any

heating systems or component(s) previously used with a non-potable water heating appliance.

If this water heater is also used for space heating

applications, all piping and components connected to

the water heater shall be suitable for use with

potable water,

_,WARNING

Toxic chemicals such as used for treatment of boilers

or non-potable water heating appliances shall never be introduced into a potable water space heating system.

NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when con- nected to copper pipe.

Page 9
Image 9
Kenmore 153.337002, 153.337072 owner manual Installation Instructions contd, Typical Installation, Awarning

153.337002, 153.337072 specifications

The Kenmore 153.337072 and 153.337002 represent a duo of high-efficiency window air conditioning units that have become popular choices for consumers seeking effective cooling solutions. Engineered with modern technology, these models promise to deliver optimal performance while maintaining energy efficiency.

One of the standout features of the Kenmore 153.337072 is its dual cooling and heating functionality. This versatility allows it to not only cool spaces during the hot summer months but also provide warmth during the chillier seasons. With a cooling capacity of 7,000 BTUs, it is suitable for rooms up to 350 square feet, making it ideal for bedrooms or small living areas. On the other hand, the 153.337002, while also a cooling unit, focuses solely on cooling performance, boasting a similar BTU capacity tailored for energy-efficient cooling.

Both models incorporate advanced energy-saving technologies. They are equipped with Energy Efficiency Ratio (EER) ratings that exceed the minimum standards set by energy regulatory bodies. This means consumers can enjoy a comfortable indoor climate without incurring high electricity bills. With features like programmable timers and sleep modes, users can manage cooling more effectively, adjusting temperature settings to minimize energy consumption.

In terms of user convenience, both units come with user-friendly remote controls, allowing easy adjustments from anywhere in the room. The digital control panel is intuitive, featuring clear LCD displays for monitoring settings. They also include multiple fan speeds and cooling modes to cater to individual preferences, ensuring a personalized experience.

Maintenance is simplified with the inclusion of washable and reusable air filters, which enhance indoor air quality by reducing dust and allergens. A filter replacement indicator alerts users when a cleaning is required, promoting optimal performance and hygiene.

In conclusion, the Kenmore 153.337072 and 153.337002 embody a blend of efficiency, user convenience, and advanced cooling technology. Whether you are looking for a unit that provides both heating and cooling or one focused solely on cooling, these models offer reliable solutions to keep indoor spaces comfortable year-round. Their commitment to energy efficiency not only benefits consumers economically but also aligns with environmentally conscious practices, making them a noteworthy choice in the air conditioning market.