Installation Instructions (cont'd)
Venting (cont'd)
All vent gases must be completelyvented to the outdoors of the
structure (dwelling). Instal[only the draft hood provided with the new water heater and no otherdrafthood.
Vent pipes must be secured at each joint with sheet metal screws.
Gas Piping
AWARNING
Makesure the gassuppliedis the same type listedon the modelns_ngpia_ The Inlntgaspressurenmstnnt exceed
10.S in. water column ('].61d_) for natuili gas or 13 in.
CHIMNEY
TO
RISE PFEc_NEAR I
!
VENT PIPE INSTALLATION
There must be a minimum of 6" dearance between single wall vent pipe and any combustible maserial. Fill and seal any deat-
ance between single wall vent pipe*and combustible material with mortar mix, cement, or other noncombustible substance.
Forother than singlewall, follow vent pipe manufacturer's dear- 0axcespecifications.To insure a
brick chimney, seal around the vent pipe with mortar mix cement.
AWARNING
Failureto havemqulrecldurances., betweenventpipingand
combustible _ will remit Ina Em hazard.
Besureventpipeisproperlyamnoctodto preventnscapeof
AWARNING]
dangemmIlueSasnswhich€ouldcausedead_asphln_o_
AWARNING
Chemicalvaporcorrosionof the flue and vent systemmay occurif air for combustioncontainscertainchemicalveporL Spraycan pmpellonts,deaningsolvents,refrigeratorKtd air conditionerrefrigerants,swimmingpool chemicals,calcium andsodiumddoride,waxe_bleach,and processchemlcalsare typicalcompoundswhicharepotentially€orrnslve.
column(3.2kPa)for propane(I.R) gas.The minimuminlet gaspressurelistedon the modelredng plate isfor the pur-
pose04'inputadjustment.
AWARNING
If the gescona'olvaiveIssubjectedto pressuresexceeding½ ] poundper squareinch(3._la_a),the damageto the
tml velvecouklrnsultin a tim or explosionfromleaidnggel J
AWARNING
] If the maingaslineshutoffservingall gasappliancesis used,] I also tom "off" the ges et each appliance. Leaveall gas appii- J
I | th" | I |
A gas line of su_cient size must be tun to the water heater. Consult the latest edition of National Fuel Gas Code ANSI
Z223.1, also referredto as NFPA54 and the gascompany concern- ing pipe size.
There mustbe:
•A readilyaccessiblemanualshut off valvein the gas supplyline servingthe water heater,and
•A dripleg (sediment trap)aheadof the gascunt_rolvalveto hdp
prevent dirt and foreign materials from entering the gascontrol valve.
•A flexible gas connector or a ground joint union between the shutoff valveand control valveto permit servicingof the unit.
Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse offsoapy solution and wipe dry.
Standard Models are for imtattadon up to 3,300 feet above sea level.
fl_h Altltud¢ Models are for insm]htion from 3,300 to 5,500 ahove sea levd.
If a standard toodd isinstalled above 3,300 feet or a high altitude model is installed above 5,500 feet, the input rating must be reduced at the rate of 4 percent for each 1,000 feet above sea level.
Contact your local Sears Service Center or gas udlity for further information.
AWARNING
The appliance and its gasconnectionmust be leaktested
befo_p_clagtheafCl_acemoperaUo_