Service and Adjustment (cont'd)
I-R Gas Control Valve & Burner
Assembly Replacement
Information
&WARNINGPROPANE (L.R) GAS CONTROL VALVE AND BURNER ASSEMBLY REPLACEMENT INFORMATION.
Temperature-Pressure Relief
Valve OperationTb_e
RELIEF VALVE
For Propane (I.R) Gas ModelsOnly:,
Your water heater is equippedwi_ • Propane
for the followingfittingsand their connections.
•The connecdon between the manifold and the gas cont_ v_ (A _o B) are left hand threads_
•The connection between the main burner orifice and che manifold (C to D) are left hand threads.
For ordering these replacement parts, please refer to the "Repair Parts" section ofthi_ manual.
/
DISCHARGE P!PE
Draining
The water heater should be drainedif being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
Turn the gas control knob to the _OI_F"position. CLOSE the cold water inlet valveto the water heater.
•OPEN a nearby hot water faucet and leave open to allow for draining.
•Connect a hose to the drain valve and terminate to an ade- quate drain.
•OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and
drained for an extended period, the dra_ valve should be left open with hose connected allowing water to terminate to an adequatedrain.
•Close the ctrainvalve.
•Follow instructions in the "Filling The Water Heater" section.
•Follow the lighting instructionsin the "Lighting" section to restartthe waterheater.
Failureto install and maintain a new properly listed tempera-
AWARNING
If the temperstur_prassererelief valveon the appliance wanpsec disd_q_s periodicall this maybe dueto thermai
expansion,Your water heater may have a checkvalve installedIn the water line or s water meter with a check
valv_ Consultthe SearsSecvicoCenterfor furthecinforma. don. Do notplugthe
tio_ male mm _at (I) no one is in front of or asound the
outlet of the _anperatemtammre relief valve disdwlle line,
and(2)_ thewmr manual/a_hargedwmnot€_.e any
pmper_ dam_e beaue thewaternW beexm._y hotIf after manually operating the valve, it _ls to completely reset anci continuesto _qease w'_er,immediate_ dose the cold water inlet to the water heater, follow the draining instructions, and replace the
21