PRODUCT DATA
Cyst Interior Water Filtration System Model
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 200 gallons (757 liters),
|
| Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi. |
|
|
|
|
|
|
| |||||
Substance | Reduction | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | ||||
Aesthetic | Effects | MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | ||||
Chlorine Taste/Odor | N/A |
| 1.9 mg/L | N/A |
| 0.06 mg/L | N/A |
| 97% |
| 994707 | |||
Particulate |
| N/A |
| 108,667/m L* | N/A |
| 45/mL |
| N/A |
| 99.96% |
| 994711 | |
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | |||||
Reduction |
| MCL |
| Infiuent | Effluent | Effluent | Reduction |
| Reduction | Number | ||||
Cyst |
| 99.95%** | 157,750/mL | 55/mL |
| 1.0/mL |
| 99.9987% |
| 99.9996% |
| 994710 | ||
Turbidity |
| N/A |
| 26 NTU | 0.5 NTU | 0.1 NTU | 98.9% |
| 99.5% |
| 994710 | |||
Lead: @ pH 6.5 | 0.015 | mg/L | 0.160 | mg/L*** | 0.011 | mg/L | 0.001 | mg/L | 93.5% |
| 99.4% |
| 994708 | |
Lead: @ pH 8.5 | 0.015 | mg/L | 0.158 | mg/L*** | 0.011 | mg/L | 0.001 | mg/L | 92.1% |
| 99.3% |
| 994709 |
•It is essential that operational, maintenance, and filter replacement requirements be carried out for this product to
perform as advertised.
•Model NLCS200 Change the cartridge at least every
Prices are subject to change without notice.
•Refer to the "Front cover" or"Assistance or Service" section for the Manufacturer's name, address and telephone number.
•Refer to the "Warranty" section for the Manufacturer's limited warranty.
Application Guidelines/Water Supply Parameters
•The product is for cold water use only.
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Water | Supply |
| City | or Well |
|
Water | Pressure | 30 | - 120 psi | (207 - 827 | kPa) |
Water | Temperature | 33 | ° - IO0°F | (0.6 ° - 37.8 | ° C) |
*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L + 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.