PRODUCT DATA

Cyst Interior Water Filtration System Model WFI-NLCS200/NLCS200

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 200 gallons (757 liters),

 

 

Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

 

 

 

 

 

 

 

Substance

Reduction

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Aesthetic

Effects

MCL

 

Influent

Effluent

Effluent

Reduction

 

Reduction

Number

Chlorine Taste/Odor

N/A

 

1.9 mg/L

N/A

 

0.06 mg/L

N/A

 

97%

 

994707

Particulate

 

N/A

 

108,667/m L*

N/A

 

45/mL

 

N/A

 

99.96%

 

994711

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum

%

Average

%

NSF Test

Reduction

 

MCL

 

Infiuent

Effluent

Effluent

Reduction

 

Reduction

Number

Cyst

 

99.95%**

157,750/mL

55/mL

 

1.0/mL

 

99.9987%

 

99.9996%

 

994710

Turbidity

 

N/A

 

26 NTU

0.5 NTU

0.1 NTU

98.9%

 

99.5%

 

994710

Lead: @ pH 6.5

0.015

mg/L

0.160

mg/L***

0.011

mg/L

0.001

mg/L

93.5%

 

99.4%

 

994708

Lead: @ pH 8.5

0.015

mg/L

0.158

mg/L***

0.011

mg/L

0.001

mg/L

92.1%

 

99.3%

 

994709

It is essential that operational, maintenance, and filter replacement requirements be carried out for this product to

perform as advertised.

Model NLCS200 Change the cartridge at least every 6-9 months. Use replacement cartridge NLCS200, part# 9002. 2001 suggested retail price of $39.95 U.S.A./S49.95 Canada.

Prices are subject to change without notice.

Refer to the "Front cover" or"Assistance or Service" section for the Manufacturer's name, address and telephone number.

Refer to the "Warranty" section for the Manufacturer's limited warranty.

Application Guidelines/Water Supply Parameters

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

Water

Supply

 

City

or Well

 

Water

Pressure

30

- 120 psi

(207 - 827

kPa)

Water

Temperature

33

° - IO0°F

(0.6 ° - 37.8

° C)

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test

requirement is 0.15 mg/L + 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.

22