![o e@ @ @](/images/new-backgrounds/56018/5601813x1.webp)
o e@ @ @
Power On/Off(1)
PressingPowerbuttononceturnsthe
"ON"andpressingit again dehumidifier
"OFF . "
turnsthedehumidifier
Setting (2)
Bypressingthisbutton,unitwillcyclethrough eachsettingwitheverypress.Theorderof settingsareAuto- CycleTimer- DelayStart
-- Auto...
Humidity
Auto (3)
Whentheunitisturnedonforthefirsttime,the unitwillbegininAutomodeAUTO. (3)willbe litand"Auto"willbedisplayedinwindow(7/8) for5 secondsbeforereturningto theambient temperatureandhumidityIn. thissetting, humiditylevelis automaticallysetfor50%RH.
Becauselowertemperaturesusuallycorrelate withlowerhumiditylevels,theunitwillnotrun frequentyAt. highertemperatureshigherhumidity isnormalsotheunitwillrunmoreoften.
Humidity
Inthissetting,Humidityallowsyouto manually setthedesiredhumiditylevelby usingthe humidityarrows(9).Humidityvaluesarechanged in5o/oincrementsrangingfrom35%to70%. Wheninthismode,therewillnotbea setting LEDlrt.Whenpressingv arrowkeywhenthe valueis35%,theunitwilloperatecontinuously. Inthiscontinuousoperation,"Cont"willbe displayedinthewindow (7/8)for5 seconds beforereturningto theambienttemperatureand humidityTo. leavecontinuousoperation,press thearrow,rorchangethesetting.
DelayStart (5)
Unitcanbeprogrammedtoturnonata desired delaytimeby pushingthetimerarrows(6)' Timecan be adjustedin t hourincrements rangirrgfrom1 to 12hours.Delaytimewillbe
showninwindow (7/8)andwillcountdownto starttimein t hourincrements.
CycleTimer(4)
Inthissetting,theunrtwillrunforeither3,6, or 12hours,thenshutofffor3,6,or 12hoursCycle. timecanbeadjustedbypushingthetimerarrow upor down(6)repeatedlyto setoperatingtime for3,6,or 12hoursThecycletimerfunctionwill continueuntilyouchangethesettingorturnthe unitoff.
FanSpeed(10)
PressFanSpeedto togglebetweenAuto,Low, andHighfanspeeds.Speedwillbeshownin fanspeedindicator(11).WhenAUTOisselected, theunitwilladjustthefanspeedaccordingly dependingonthehumiditylevelThe.orderof
- - Low- Auto...
fanspeedsettingsisAuto High
BucketFull Indicator(12)
Whenthecollectionbucketisfull,BUCKETFULL
indicator(12)willcomeon .Thedehumidifierwill
notrununtilthebucketis emPtY.
Pump On/Off(1a)
PumpOnisanoptionalsettingwhenusingthe
'/o" hoseto removethecollected supplied drain
waterinthebucketToturn. thepumpon/off,press thePumpButton(14)When.thepumpison,Pump Display(13)willlighton .ThePumpDisplay(13) willbeoffwhenthepumpisoff.Thepumpshould onlybeturnedonwhenthereisa %"drainhose properlyconnectedtothemachineandthepump isintendedtobeused.lfthepumpbuttonispressed whenusingotherwaterdisposaloptions,E3(Error Message)willshowondisplaypanel,Pumpwillrun automaticallywheneverthebucketgetsfull.The bucketmaynotemptycornpletelyto protectthe pump,butoncethebucketfillsupagain,thepump willrun .
o