Problem | _ |
| Possible | Causes | Solutions |
|
|
|
|
| |||
Dehumidifier | does not | The dehumidifier is un- | Make sure the dehumidifier's plug is pushed | ||||||||||
start, |
|
| plugged, |
|
|
| completely into the outlet. |
|
|
| |||
|
|
| The fuse | is blown t cir- | Check the house fuse t circuit breaker box and | ||||||||
|
|
| cult breaker | is tripped, | replace fuse or reset breaker. |
|
| ||||||
| i |
| Dehumidifier | has |
| The dehumidifier | automaticaliy | turns | off when | ||||
|
|
| reached the user set | either | conditionoccurs. Change to a lower | ||||||||
|
|
| humidity | level or the | setting or empty the water | bucket and replace | |||||||
|
|
| bucket is full. |
| properly. |
|
|
|
|
| |||
|
|
| Bucket is not in the | The bucket must be in place and securely | |||||||||
|
|
| proper position, |
| seated | for the dehumidifier | to operate. | ||||||
|
|
| Power Failure. |
| There | is a protectivetime | delay (up to 3 rain.) | ||||||
|
|
|
|
|
|
| to prevent trippingof the compressor overload. | ||||||
|
|
|
|
|
|
| For this reason, the unit may not start normal | ||||||
|
|
|
|
|
|
| dehumidification for 3 min. after it is powered | ||||||
|
|
|
|
|
|
| back on. |
|
|
|
|
| |
|
|
|
|
|
|
|
| , ,,, | ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, |
|
|
| |
Dehumidifier | is not | Not enough | time | allowed | When | first installed, allow | at least 24 hours to | ||||||
operating | as |
| for unit to remove | tools- | achieve the desired humidity level. |
| |||||||
Intended. |
|
| ture. |
|
|
|
|
|
|
|
|
|
|
|
|
| Airflow is restricted. | Make sure there are no curtains, blinds, or | |||||||||
|
|
|
|
|
|
| furniture blocking the side or back of the de- | ||||||
|
|
|
|
|
|
| humidifier. |
|
|
|
| ||
|
|
| Dirty filter. |
|
| See the Cleaning The Air | Filter section | ||||||
|
|
| The user set Humidity | To reduce moisture, press the down | arrow | ||||||||
|
|
| Level may not be set low | button to lower the percent humidity | desired in | ||||||||
|
|
| enough, |
|
|
| the room, | or set the dehumidifier to CO for | |||||
|
|
|
|
|
|
| continuous | operation. |
|
|
| ||
|
|
| Doors and windows may | Check that all doors, windows, | and other | ||||||||
|
|
| not be closed tightly, | openings are securely closed. |
|
| |||||||
|
|
| Water is not draining | Make sure the drain is placed | below the drain | ||||||||
|
|
| through drain hose | connector nozzle to allow gravity to drain the | |||||||||
|
|
|
|
|
|
| iwater (Refer to Gravity Drain Hose section in | ||||||
|
|
|
|
|
|
| :this manual). |
|
|
|
| ||
|
|
| Room temperature is too | Moisture removal | is best at higher room tern- | ||||||||
|
|
| tow. |
|
|
| peratures. Lower | room temperatures | will re- | ||||
|
|
|
|
|
|
| duce the moisture removal rate. This model is | ||||||
|
|
|
|
|
|
| designed to operate at temperatures above | ||||||
|
|
|
|
|
|
| 41°F. |
|
|
|
|
|
|
Filter Indicator is ]it. | Filter needs to be | Once filter has been cleaned, press the FIL- |
i cleaned every 250 hours of use.
TER button for 3 seconds to turn the filter indicator off.
9