Kenmore 580.72184 Installation Requirements Installation Hardware, Interiorwall, FIG. t

Models: 580.72184

1 23
Download 23 pages 59.29 Kb
Page 5
Image 5
INSTALLATION REQUIREMENTS INSTALLATION HARDWARE

INSTALLATION REQUIREMENTS INSTALLATION HARDWARE

Your air conditioner will install into standard double

hung windows with actual clear opening widths of 29 to 4t inches (737mm to 1041mm) (FIG, 1)

Lower sash must open sufficiently to allow a clear

vertical opening of 18 inches (457mm). Side louvers and the rear of the air conditioner must have clear

air space to allow enough airflow through the condenser for heat removal. The rear of the unit

must be outdoors, not inside a building or garage,

l

Interiorwall

..-

FIG. t

ELECTRICAL SERVICE

Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on right side of cabinet).

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding, Do not change plug in any way. Do not use an adapter plug, If your present wall outlet does not match your plug, call a qualified electrician to

make the necessary corrections.

SAVE CARTON and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.

To avoid risk of personal injury,property damage, or product damage due to the weightof this device and sharp edges that may be exposed:

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

Carefully inspect location where air conditioner will be installed.Besure it will support the

weight of the unit over an extended perior of time.

°Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.

°Make sure air conditioner does not fall during installation.

-5-

AB C D E

F G H I J K

 

 

FIG. 2

ITEM

NAME OF PARTS

Q'TY

A

SIDE CURTAIN

2

B

SUPPORT BRACKET

2

C

SILL BRACKET

2

D

LOCK NUT

4

E

SCREW: 25/64"

11

F

SCREW: 13/1#`

7

G

SCREW: 9/16"

5

H

M-SCREW

2

I

CARRIAGE BOLT

2

J

FOAM STRIP

1

K

FOAM SEAL

1

L

WINDOW LOCKING BRACKET

1

M

DRAIN PIPE

1

REQUIRED TOOLS:

°Tight Fitting gloves

Standard screwdriver

Phillips screwdriver

Pliers

Sharp knife

3/8-inch open end wrench or adjustable wrench

1/4-inch hex socket and ratcher

Tape measure

°Electdc drill

°1/4-inch drill bit

Page 5
Image 5
Kenmore 580.72184 owner manual Installation Requirements Installation Hardware, Interiorwall, FIG. t, Electrical Service