BEFORE CALLING FOR SERVICE

BEFORE CALLING FOR SERVICE

Check the following list to be sure a service calI is reaIly necessary. A quick reference to this manual may help you avoid an unneeded service call.

THE AIR CONDITIONER WILL NOT OPERATE

Check if..,

Then.,.

 

The Current interrupterdevice is tdped.

Press the RESET button locatedon the power cord plug

 

 

Ifthe RESETbutton will not stay engaged,discontinue use of the

 

 

air conditionerand contact a quaIifiedservicetechnician.

 

Wall plugdisconnected.

Pushplugfirmlyintowalloutlet.

 

Housefuseblownor circuitbreakertripped.

Replacefuse withtimedetaytypeorresetcircuitbreaker.

 

PowerisOFF

Pushthepowerbutton.

 

Unitwasturnedoff andthenon tooquickty.

Setunit offandwait3 minutesbeforerestarting.

 

TEMPControlset warmerthanroomtemperature

Set TEMPControlto a Iowernumber.

 

AIR FROM UNIT DOES NOT FEEL COLD ENOUGH.

 

Check if..,

Then.,.

 

FAN SPEEDset at LOW.

PushFAN SPEEDbuttonto set at HI.

 

TEMPControlset toowarm

SetTEMPControlto a lowertemperature.

 

Roomtemperaturebelow70'F(21C).

Coolingmaynotoccuruntil roomtemperaturerisesabove70'F(21oC)

 

Temperaturesensingtubetouchingevaporatorcoil,

Straightentubeawayfrom evaporatorcoil

 

locatedbehindfront grille

 

 

THEAIRCONDITIONERCOOLING,BUTROOMISTOOWARM- ICEFORMINGONCOOUNGCOILBEHINDINLETGRILLE.

 

Check if...

Then...

 

Outdoortemperaturebetow70"F (21C)

To defrostthe coil,set theMODEto FAN,FANspeedto High

 

Air filtermaybedirty

Cteanair filter Referto Maintenancesectionof owner'smanual

 

 

Todefrostthecoil,settheMODEto Cool,Fan speedto high,andthe

 

TEMPControlset toolow

Tempcontrolto a highertemperature

 

THEAIRCONDITIONERCOOLING,BUTROOMISTOOWARM

 

Check if...

Then...

 

Dirtyair filter- air restncted.

Cleanair filter Referto Maintenancesectionof owner'smanual.

 

TEMPControlset toowarm

SetTEMPControlto a towertemperature.

 

Frontofunit is blockedbydrapes,blinds,furniture,etc.

CIearblockageinfrontof unit.

 

Air distributionis restricted.

 

 

Doors,windows,registers,etc open Coldair escapes.

Closedoors,windows,registers,etc.

 

Unitrecentlytumedon in hotroom.

Allowadditionaltimetoremovestoredheatfromwalls,ceilingfloorandfurniture

THE AIR CONDITIONER TURNS ON AND OFF RAPIDLY,

 

Check if,..

Then,..

 

Outsidetemperatureis extremelyhot.

Set FANSPEEDon HIto minimizethecoolingload

 

Unitisset to energysavermode

Approximatelyevery3 minutesthefanwiltturnon andtheunitwillcheck

 

 

theroomair temperatureto determineif coolingis needed.Thisis normal

 

 

energysavermodeoperation.

 

NOISE WHEN UNIT IS COOLING.

 

 

Check if,..

Then,..

 

Soundoffanhittingwater- fromthemoistureremovalsystem

Ttlis is normalwtlenhumidityis high.Closedoors,v,Andows,andregisters

W ndowv bra on - poor nsta ation.

Refer o nsta a on ns ructons orcheckw th ns a er.

 

WATER DRIPPING INSIDE ROOM WHEN UNIT IS COOLING.

 

Check if,..

Then,..

 

Theair conditioneris improperlyinstalled.

Tilt airconditionerslightlyto theoutsideto allowwaterdrainage.Referto I

 

installationinstructionsor checkwithinstalIer.

I

WATER DRIPPING OUTSIDE WHEN UNIT IS

COOLING.

 

Check if...

Then.,.

 

The unitis removinglargequantitiesofmoisture

Thisis normalduringexcessivelyhumiddays.

 

from humidroom.

 

 

-14-