Kenmore 580. 75063, 580.75123 115V~, Observeall Local Codesand Ordinances, 230V ~, Using

Models: 580. 75063 580.75123

1 32
Download 32 pages 60.32 Kb
Page 4
Image 4
OBSERVEALL LOCAL CODESAND ORDINANCES.

OBSERVEALL LOCAL CODESAND ORDINANCES.

DO NOT,UNDERANY CIRCUMSTANCES,REMOVE THE POWERSUPPLY CORD GROUNDPRONG.

ELECTRICAL GROUNDIS REQUIREDON THIS APPLIANCE.

For 230/208volt 60 Hz, AC only, 15Afusedand properlygroundedelectricalsupply is required A time delayfuse or time delay circuit breakeris recommended Usea dedicatedcircuit,serving only

this appliance.

DO NOTUSE AN EXTENSIONCORD.

115V~

230V ~

F

RECOMMENDEDGROUNDINGMETHOD Foryourpersonalsafety,thisappliancemustbegrounded. Thisappliancehasa powersupplycordwitha 3-prong groundingplug.To minimizepossibleshockhazard,the cordmustbepluggedintoa matinggroundingtypewall receptacleandgroundedinaccordancewiththe National ElectricalCode(ANSI/NFPA70)latesteditionandalllocal codesandordinances,if amatingwall receptacleis not available,it is the personalresponsibilityandobligationof thecustomerto havea properlygrounded3-prongwall rece)tacteinstalIedby aqualifiedelectrician.

Powercordmayincludea currentinterrupter device Atest andresetbuttonis providedon the plugcase.Thedeviceshouldbetestedon a periodicbasisby firstpressingtheTESTbutton andthenthe RESETbutton Ifthe TESTbutton doesnottripor if the RESETbuttonwillnot stay engaged,discontinueuseofthe airconditionerand contacta qualifiedservicetechnician.

NOTE: The shape may be different according to its rnodet

Use Wail Receptacle

Standard 125V,

3-wire grounding

receptacle rated 15A. t25V AC

Standard 250V, 3-wire grounding

receptacle rated r5A, 250V AC

Standard 250V,

3-wire grounding

receptacFe rated 20A, 250V AC

Power Supply

Use I5 AMP. time

delay fuse or 15 AMP circuit breaker

Use 20 AMP. time delay fuse or 20 AMP circuit breaker

Electrical Shock Hazard

Plug into a grounded 3 prong outlet Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

You can choose between

the two methods below according to your preference and window

sill shape.

USING

SLIT "A"

 

USING

SLIT "B"

 

Fasten

the stopper using

Type A screw, and lead the

Fasten the stopper using left screw

hole, and rotate

power

cord out through slit "A".

properly

to lead the power cord out

through slit "B".

Screw

Screw (Type ,_

,)

-4-