D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1)Remove the vent grille.
(2)Remove mount, all.
(3)Remove outcase.
(4)Disconnect the wireleads.
(5)Remove the three screws and Magnetron very carefully.
Vent Grille
NOTES:
•When removing the magnetron, make sure that its dome does not hit any adjacent parts, or it may be damaged.
•When replacing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition.
•After replacing the magnetron, check for microwave energy leakage with a survey meter Check microwave energy leakage must be below the limit of 5 mW/cm2. (All service adjustments should be made for minimum microwave energy leakage readings.)
Outcase
Figure 11 | Figure 12 |
Figure 13