correctly connected Relay 2.

COMPONENTS

TEST PROCEDURES

 

RESULTS

 

 

Check for continuity of relay 2 with an

POWER

 

 

 

LEVEL

 

 

 

ohm-meter.

 

 

 

 

 

 

 

(Remove wire leads from relay 2 and

1

4 sec

18 sec

 

operate the unit.)

 

 

 

 

 

 

2

6 sec

16 sec

 

Relay 2

3

8 sec

14 sec

 

 

4

10 sec

12 sec

RELAY2

 

5

12 sec

10 sec

 

 

 

 

6

14 sec

8 sec

 

 

7

16 sec

6 sec

 

Figure 30

8

18 sec

4 sec

 

9

20 sec

2 sec

 

CAUTION: The relay connector 2 must be

 

10

22 sec

0

 

correctly connected Relay 2.

 

 

 

 

NOTES:

A MICROWAVE ENERGY TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON.

MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.

WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE CONNECTOR, NOT THE WIRES.

B. CHECKOUT PROCEDURES

(1) CHECKOUT PROCEDURES FOR FUSE BLOWING

CAUTION: REPLACE BLOWN FUSE WITH 20 AMPERE FUSE.

PROBLEMS

CAUSES

Fuse blows immediately after

 

the door is closed.

Improper operation of the primary interlock, secondary

 

Fuse blows immediately after

interlock switches and/or the interlock monitor switch.

the door is opened.

 

 

 

Fuse blows when the door is closed and START

Malfunction of the high voltage transformer; the high

key is touched.

voltage capacitor including the diode, the magnetron,

 

the blower motor or the circuit board.

 

 

NOTES:

If the fuse is blown by an improper switch operation, replace all switches and the fuse at the same time. After replacing the defective switches with new ones, make sure that they are correctly connected.

Check for microwave energy leakage according to INTERLOCK ADJUSTMENT PROCEDURES on page 7-12 when the primary interlock, secondary interlock switches and/or the interlock monitor switches are adjusted or replaced.

7-18

Page 30
Image 30