Kenmore 796. 8147#, 796.9147# Final Installation Check, Testing Dryer Heating, Checking Venting

Models: 796. 8147# 796.9147#

1 35
Download 35 pages 30.23 Kb
Page 17
Image 17

FINAL INSTALLATION CHECK

Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following steps and tests.

1Is gas turned on? (Gas models only)

2Is dryer plugged in? Dryer should always be plugged into the proper outlet.

Gas dryer should use a

120-VAC, 60-Hz. grounded

3-prong outlet.

Electric dryer should use a

4-wire connection which is required for all mobile and manufactured home installations, as well as all new construction after

January 1, 1996.

-- OR --

A 3-wire connection. NOTE: A 3-wire connection is NOT permitted on new construction after January 1, 1996.

3Is the dryer transition duct from dryer to wall connected? Make sure the transition duct behind the dryer is properly connected and is not crushed or damaged.

4Is dryer level? Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all four leveling feet rest firmly on the floor.

5Is the dryer heating normally? Perform the following dryer heating test.

INSTALLATION INSTRUCTIONS

Testing Dryer Heating

1Close the dryer door.

2Press the POWER button to turn the dryer on.

3Turn the cycle selector knob to Normal drying cycle.

4Press the START/PAUSE to start the dryer. After three minutes, open the dryer door and check that the air inside is warm.

NOTE: If the air inside the dryer is not warm after three minutes, there may be air in the gas supply line to the dryer, and the gas igniter may turn off before the main burner ignites. When this happens, the igniter will continue to attempt main burner ignition until all air is purged from the line. Once ignition occurs, the air inside the dryer will become warm.

Checking Venting

Vent ductwork should be checked for lint buildup and cleaned at least once per year. If any noticeable reduction in drying performance occurs, check duct for obstructions and blockages.

17

Page 17
Image 17
Kenmore 796. 8147#, 796.9147# manual Final Installation Check, Testing Dryer Heating, Checking Venting