INSTALLATION INSTRUCTIONS

KEY DIMENSIONS AND SPECIFICATIONS

 

Description

Dryer (Gas and Electric)

 

 

Electrical Requirements

Refer to the rating label

 

 

Gas Requirements* NG:

4–10.5 inches WC (Water Column)

 

 

Gas Requirements* LP:

8–13 inches WC

 

 

Dimensions

27 in. (W) X 30 1/4 in. (D) X 38 in. (H), 52 ¼ in. (D with door open)

 

 

68.6 cm (W) X 76.7 cm (D) X 96.5 cm (H), 132.7 cm (D with door open)

 

 

Net Weight

Electric : 147 lb. (66.7 kg) Gas : 150.5 lb. (68.3 kg)

 

 

 

 

 

Drying Capacity

IEC 7.4 cu. ft.

 

 

 

 

 

*Gas Models Only

 

 

LOCATION REQUIREMENTS

IMPORTANT: Read all installation instructions completely before installing and operating your dryer.

Standard Installation – Side View

It is important that you review this entire manual before installing and using your dryer. It contains detailed instructions concerning electrical connections, gas connections and exhaust requirements.

CHOOSE THE PROPER LOCATION

Store and install the dryer where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.

Choose a location with a solid, level floor.

If the dryer is being installed in a garage, place the dryer at least 18 inches (45.7cm) above the floor.

Properly ground the dryer to conform with all governing codes and ordinances.

To reduce the risk of electric shock, do not install the dryer in damp or wet locations.

IMPORTANT: If you are installing your dryer in a manufactured or mobile home, please refer to the

20 1/8 in.

 

(56.2 cm)

 

(10 cm)

30 1/4 in.

 

(76.7 cm)

52 ¼ in.

(132.7 cm)

Standard Installation – Front View

4 in.

 

 

(10 cm)

 

 

1 in.

 

1 in.

(2.5 cm)

27 in.

(2.5 cm)

 

 

 

(68.6 cm)

 

Special Electrical Requirements for Mobile or Manufactured Homes section.

CLEARANCES

Most installations require a minimum 5 ½ inch (14 cm) clearance behind the dryer for the exhaust ducting.

Allow minimum clearances of at least 1 inch (2.5 cm) on the sides and back to minimize vibration and noise.

Allowing additional clearance for installation and servicing is recommended.

Be sure to allow for wall, door, or floor moldings that may increase the required clearances.

Allow at least 21 inches (53.3 cm) in front of the dryer to open the door.

3"

(7.6 cm)

Vent 48 sq. in.

(310 sq. cm. )

Vent

24 sq. in.

(155 sq. cm. )

3"

(7.6 cm)

Additional instructions for closet installations:

The closet door must allow for sufficient airflow. Refer to the diagram above for minimum vent opening requirements. A louvered door is also acceptable.

8

Page 8
Image 8
Kenmore 796.9147# manual KEY Dimensions and Specifications, Location Requirements, Choose the Proper Location, Clearances