Controls

Operations of the following control and switches are required in accordance with the center unit and speakers connected with this unit.

FUSE(20A)

BATT

POWER IN

SERVO ΙΙ

 

SERVO ΙΙ

20

GND

SPEAKER OUTPUT

 

 

 

P.CON(REMOTE)

 

 

FUSE(20A)

20

1 2 3

4

5

6

15Hz

LPF

 

INPUT

 

 

OFF 25Hz

FREQUENCY(Hz)

SENSITIVITY(V)

 

LINE IN

INFRASONIC

100

150

0.5

0.3

L

R

 

1

 

 

 

 

 

 

 

 

70

 

2

 

GND

 

 

50

200

345

0.2

 

 

78 90 !

SPEAKER LEVEL INPUT

LEFT RIGHT

MONO

POWER AMPLIFIER

@

1FUSE (20 A 2)

2Battery terminal

3Ground terminal

4Power control (REMOTE) terminal

5Speaker output terminals

As this unit accepts speakers with a minimum impedance of 2 ohms, connect speakers with 2-ohm or higher impedance to these terminals.

2CAUTION

The rated input of the speakers should be no less than the maximum output of the amplifier. Otherwise malfunction may result.

6SIGMA SERVO FEED BACK terminals (See p.8)

2CAUTION

Be sure to make proper connections to the SIGMA SERVO FEED BACK terminals. Incorrect connection may result in lack of sound output or other malfunctions.

7INFRASONIC FILTER switch

Ultralow frequencies that cannot be reproduced even by a subwoofer speaker do not become sound but become unnecessary oscillations, which affect the sound by causing distortion, etc. Setting this switch to "15 Hz" or "25 Hz" cuts the frequencies below the respective frequency. This improves the reproduction performance of the speakers by eliminating unnecessary oscillations which will not become sound.

8LOW PASS FILTER FREQUENCY control

This control adjusts the frequency band output from this unit.

9INPUT SENSITIVITY control

Set this control according to the pre-output level of the center unit connected with this unit, or to the maximum power output of the genuine- accessory car stereo.

Use the diagram on the right as a guide.

 

10

 

 

 

0.5

15

1

0.3

 

 

2

3

25 45 (V) 0.2

(W)

4English

Page 4
Image 4
Kenwood KAC-818 Controls, Sigma Servo Feed Back terminals See p.8, Infrasonic Filter switch, Input Sensitivity control