Connection

* Commercially available parts

2WARNING

To prevent fire caused by a short in the wiring, connect a fusible link or breaker nearby the battery’s positive terminal.

2CAUTION

If sound is not output normally, immediately turn power off and check connections.

Be sure to turn the power off before changing the setting of any switch.

If the fuse blows, check wires for shorts, then replace the fuse with one of the same rating.

Check that no unconnected wires or connectors are touching the car body. Do not remove caps from unconnected wires or connectors to prevent short circuits.

Connect the speaker wires to appropriate speaker connectors separately. Sharing the negative wire of the speaker or grounding speaker wires to the metal body of the car can cause this unit to fail.

After installation, check that the brake lamps, winkers, and wipers work properly.

CENTER UNIT (CD receiver, etc.)

Lead terminal*

Power control wire

30

30

 

 

FUSE(30A2)

POWER

Terminal cover

Battery wire*

Protective Fuse*

RCA cable*

RCA cable ground

terminalB channel input

GND

 

 

A channel

 

 

input

 

 

 

 

5

 

 

4

67

 

23

 

8

 

10

9

 

 

 

ID NUMBER TO H/U

REMOTE RESET

A channel

Right speaker

A channel

Left speaker

B channel

Right speaker

B channel

Left speaker

Bridged Connections

A channel

Speaker (Bridged)

Battery

Ground wire*

B channel Speaker (Bridged)

LX-Bus connection

CENTER UNIT

Power control wire

30

30

 

 

FUSE(30A2)

POWER IN

Master amplifier

Extension wire*

30

30

 

 

FUSE(30A2)

POWER IN

Slave amplifier 1

30

30

 

 

FUSE(30A2)

POWER IN

Slave amplifier 7

To Kenwood disc changer/

Set the ID number of the Master amplifier to "0".

External optional accessory

You can connect up to 7 Slave amplifiers. Assign them ID numbers "1"

 

 

 

 

 

 

 

 

 

 

 

 

to "7" and do not duplicate them.

Control cable

2 CAUTION

• Do not connect 2 Master amplifiers to the Center Unit. If done, you

(option)

cannot control all amplifiers connected to the Center Unit.

 

 

 

 

 

 

 

 

 

 

 

 

• The LX AMP and the sensor unit cannot be connected

 

 

 

 

 

 

simultaneously. You must connect any of them at a time.

 

 

 

 

 

 

NOTE

 

 

 

 

5

 

• The total length of S-video cables you can connect is 14 meters

 

 

 

4

67

(46 ft) maximum. If the cable length exceeds this limit, you cannot

 

 

23

 

8

 

 

ID NUMBER TO H/UREMOTE RESET

 

 

 

1

0

9

 

"0"

 

5

6

 

control amps from the Center Unit.

4

 

• If you assign the same ID number to multiple amplifiers, they

2

0

9

8

1

 

 

 

3

 

 

7

 

 

ID NUMBER

malfunction when you operate any of them from the Center Unit.

 

• If you assign ID number "8" or "9" to a Slave amplifier, it is not

 

 

 

 

 

 

S-video cable*

recognized by the Center Unit.

RCA cable*

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

4

67

 

 

 

23

8

 

 

 

 

10

9

 

 

 

ID NUMBER TO H/U

RESET

"1" – "7"

4

5

6

 

1

0

9

 

 

3

 

 

7

 

 

2

 

 

8

 

 

 

 

 

 

ID NUMBER

Not more than 14m (46 ft)

 

5

 

 

 

4

 

67

 

 

 

23

 

8

 

 

 

1

0

9

 

 

 

ID NUMBER

TO H/U

REMOTE

RESET

"1" – "7"

4

5

6

3

 

7

 

8

2

 

1

0

9

 

 

ID NUMBER

4English