Amplifier Control System

Display mode

You can set up the display items as follows:

1Enter Menu mode

Press the [MENU] button. "VOLT"/"CURR"/"TEMP"/"FAN" is displayed.

2Select a display itemPress the [2] or [3] button.

The display items are switched in the following sequence.

Display

Information

"VOLT"

Indicates the source voltage (V).

"CURR"

Indicates the current consumption (A).

"TEMP"

Indicates the internal temperature (°F/°C).

"FAN"

Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF".

3Exit Menu modePress the [MENU] button for at least 1 second.

NOTE

When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is displayed.

Separate Amp Control

The following explains how to control the sound of amplifier B using the Amplifier Control of the unit.

1Enter Menu mode

Press the [MENU] button.

2Select the Menu item Press the [MENU] button.

The setup items are displayed approximately 1 second first, then the set values are displayed.

3Adjust the Menu item Press the [2] or [3] button.

The setup items and set values are switched as follows.

DisplayRangeAdjustment Item

"VOLT"/"CURR"/"TEMP"/"FAN"

For the operation method refer to <Display mode>

"BASS"

60/80/100/200 (Hz)

Bass Center Frequency

"BA G"

B–15 — B+15 (dB)

Bass level

"BA Q"

Q1.00/Q1.25/Q1.50/Q2.00

Bass Q Factor

" EXT"

ON/OFF

When the bass extend is set to ON, low frequency response is

extended by 20%.

 

 

"TREB"

10/12/15/17 (kHz)

Treble Center Frequency

"TR G"

T–15 — T+15 (dB)

Treble level

"VOL"

–20 — 0 (dB)

Volume offset

"TEMP"

FAHR (Fahrenheit) or

The Fahrenheit or Centigrade temperature unit can be selected

CELS (Centigrade)

for the Display mode.

 

"DEFA"

 

For the operation method refer to <Default>

"AMP"

0 — 7

The ID Number you have assigned is displayed.

 

 

Indicator

FAN

VOLT

MENU

TEMP

CURR

 

2 / 3

4Exit Menu mode

Press the [MENU] button for at least 1 second.

NOTE

When you hold down the [3] button 3 or more seconds during ID number display ("AMP"), message "MEMO" is displayed and you can register the values you have set with the Amplifier Control. To call the Amplifier Control’s values, hold down the [2] button 3 or more seconds during ID number display ("AMP"). Then, you can recall the value when message "LOAD" is displayed.

Default

Resets all values you have set to the initial (default) values.

1Enter Menu mode

Press the [MENU] button.

2Select Default mode Press the [MENU] button. Select the "DEFA" display.

3Resets the value to its default

Press the [3] button for at least 2 seconds. Message "----" is displayed, and the value is initialized.

4Exit Menu mode

Press the [MENU] button for at least 1 second.

NOTE

Volume offset value can not be initialized.

Display Demonstration

The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly.

Press the [MENU] button for at least 2 seconds.

The indicator flashes in the Demonstration mode.

Canceling the Demonstration modePress any button to cancel the Demonstration mode.

6English