Item
Condition Measurement Adjustment
Specifications/
Remarks
Test-
equipment Unit Terminal PartsUnit Method
PC test modePanel tuning mode
ADJUSTMENT
NX-800
56
12.
Single Tone
Deviation
(2TONE
deviation
adjust)
adjust *4
[Narrow]
[Wide]
13.
MSK
Deviation
adjust *4
[Narrow]
[Wide]
14.
CWID
Deviation
adjust *4
[Very Narrow]
1)
Adj item:[An TONE]
Adjust:[****]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [ ] key to store
the adjustment value.
1)
Adj item:[Aw TONE]
Adjust:[****]
PTT : ON
Press [ ] key to store
the adjustment value.
1) Adj item:[An MSK]
Adjust:[****]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [ ] key to store
the adjustment value.
1) Adj item:[Aw MSK]
Adjust:[****]
PTT : ON
Press [ ] key to store
the adjustment value.
1)
Adj item:[Nv CWID]
Adjust:[****]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : ON
Press [ ] key to store
the adjustment value.
1)
Adj item:[Single Tone
Deviation (Narrow)]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1)
Adj item:[Single Tone
Deviation (Wide)]
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[MSK
Deviation (Narrow)]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[MSK
Deviation (Wide)]
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
1) Adj item:[CWID
Deviation]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : Press [Transmit]
button.
Press [Apply] button to
store the adjustment value.
Deviation
meter
Oscilloscope
ANT Write the value as
followings.
513 (Reference
value)
Write the value as
followings.
513 (Reference
value)
Write the value as
followings.
375 (Reference
value)
1.40~1.60kHz
2.90~3.10kHz
1.40~1.60kHz
2.90~3.10kHz
0.90~1.10kHz
[Panel
tuning
mode]
[],[ ]
[PC test
mode]
[],[ ]
*4: Refer to the “Mode, Signaling, Necessary adjustment and order” table on page 57.