Item
Condition Measurement Adjustment
Specifications/
Remarks
Test-
equipment Unit Terminal PartsUnit Method
PC test modePanel tuning mode
ADJUSTMENT
NX-800
60
6. Low RSSI at
-118dBm
adjust *7
[Analog
Narrow]
[Analog
Wide]
[NXDN Very
Narrow]
1)
Adj item:[An LRSSI]
Adjust:[***]
2) Adj item:
[AnL LRSSI]→
[AnL’ LRSSI]→
[AnC LRSSI]→
[AnH’ LRSSI]→
[AnH LRSSI]
SSG output :
-118dBm (0.28µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[Aw R
LRSSI]
Adjust:[***]
2) Adj item:
[AwL LRSSI]→
[AwL’ LRSSI]→
[AwC LRSSI]→
[AwH’ LRSSI]→
[AwH LRSSI]
SSG output :
-118dBm (0.28µV)
(MOD: 1kHz,
Dev: ±3kHz)
1)
Adj item:[Nv LRSSI]
Adjust:[***]
2) Adj item:
[NvL LRSSI]→
[NvL’ LRSSI]→
[NvC LRSSI]→
[NvH’ LRSSI]→
[NvH LRSSI]
SSG output :
-118dBm (0.28µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[Low RSSI
(Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-118dBm
(0.28µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[Low RSSI
(Wide)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-118dBm
(0.28µV)
(MOD: 1kHz,
Dev: ±3kHz)
1) Adj item:[Low RSSI
(Very Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-118dBm
(0.28µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
SSG ANT
Ext.SP
connector
[Panel test mode]
After input signal
from SSG, press
[] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the
adjustment value.
Adjust with the
analog signal.
*7: Because “RSSI at -118dBm adjust” of NXDN Narrow is adjusted by adjusting “RSSI at -118dBm adjust [Analog Narrow]”, it is not necessary to
adjust “RSSI at -118dBm adjust” of NXDN Narrow.