c.After setting the desired AUTO-OFF time,
press the MENU button four times to
scroll through the remaining program-
ming options and exit the programming
mode. 'AUTO OFF SET' will now be dis-
played to indicate that it has been set.
d.To cancel the AUTO-OFF feature, press
the MENU button twice to reach the
AUTO-OFF programming mode. Press
and release the blue Cup button under
the blinking H to advance one hour at a
time until ‘OFF’ is displayed.
3. Program your Brewer for a specific Auto
On/Off Time.
a.After setting the correct time (required),
press the Menu Button three times to
program the Auto On time feature. The
LCD Control Center will show the pro-
gramming options with a small arrow
next to 'SET ON TIME'.
b.Press or hold the blue Cup button under
the H to scroll through the hours to your
desired ON time hour.
c. Press or hold the blue Travel Mug
button under the M to scroll through the
minutes to your desired ON time
minutes.
d. After setting the desired time, press the
Menu Button to save the On Time and
move to the SET OFF TIME.
e.If you want to set an OFF time, repeat
the procedure above in steps b & c to
set your desired OFF time.
f. To complete the process, press the
Menu Button two more times to exit the
programming mode. The Control Center
will now indicate the options you have set.
g. The AUTO ON time and AUTO OFF time
functions operate independently from
one another. To cancel either set func-
tion, follow the steps above and use the
H and M buttons to advance to 12:00
AM. When you reach 12:00 AM, the
Control Center will display ‘OFF’ and the
function will be disabled.
EXAMPLE: If you chose to set the On Time at
6:15 AM and the Off Time for 10:00 PM, then
the Brewer will be ‘ON’ and maintain hot
water in the tank during that time so that it is
always ready for you to brew. If you wanted
to brew outside this window, simply press the
Power Button and you can brew as soon as
the water is heated and the ‘READY TO
BREW’ indicator is displayed on the LCD
Control Center.
READY
SET ON
CLOCK
AUTO OFF
TIME
BREW TEMP
MENU
HM
AM
NOT
READY
SET
CLOCK
AUTO OFF
BREW TEMP
MENU
HM
OFF TIME
NOT
OFF
Programming Brew Temperature
(187° - 192º F)
The Brewer brews coffee at a preset tempera-
ture of 192 degrees. You can adjust this tem-
perature down by 5 degrees if you prefer a
cooler cup of coffee or tea. Simply follow the
instructions below.
1. Press the Menu Button on the LCD Control
Center five times to program the Brew
Temperature feature.
2. The LCD Control Center will now display
the programming options with a small
arrow next to ‘SET BREW TEMP’. Also, the
temperature 192 (initial setting) will be dis-
played at the bottom of the LCD Control
Center to indicate the current temperature
setting.
3. A minus sign will appear over the Cup
button and/or a plus sign over the Travel
Mug button. Use these buttons to raise or
lower the temperature one degree at a
time.
4. Once you have reached your desired brew
temperature, press the MENU button once
to exit the programming mode. ‘BREW
TEMP SET’ will be displayed in the LCD
Control Center if you have changed it from
192°.
5. To change the brew temperature again,
repeat steps 1 through 3 to change the
temperature up and/or down, remembering
that the temperature can only be between
187 degrees and 192 degrees.
READY
BREW
AUTO OFF SET
MENU
AM
TO
READY
SET
CLOCK
AUTO OFF
ONOFFTIME
BREWTEMP
MENU
º
NOT
192
NOTE: To use this programming feature,
the clock must be set to the correct time.
The clock will not be displayed unless the
time is set.
NOTE: The AUTO OFF Timer and the AUTO
ON/OFF Time programming options operate
independently, but can also be programmed
to work together. For example, you can set
the AUTO ON Time function to turn on at
7:00 AM and then set the AUTO OFF Timer
function to turn off the Brewer two hours
after the last brew.
READY
BREW
AUTO OFF SET
ON TIME SET
MENU
AM
TO