Power Cable Calculation

Power Cable Calculation

(Total RMS power output into 4Ω) x 2 = (Total input wattage [Watts])

(Total input wattage)

= (Maximum input current [Amps])

(Supply Voltage)

Example: Amplifier with a rating of 100 watts per channel into 4Ω 200 x 2 = 400 Watts (Total input power)

400 Watts / 12.5 Volts = 32 amps (Total maximum draw) Use this value of current draw to determine wire size from the chart below.

Power Wire Chart

Minimum Gauge wire

Draw

Up to

4 to

7 to

10 to

13 to

16 to

19 to

22 to

(Amps)

4 ft.

7ft.

10ft.

13 ft.

16 ft.

19 ft.

22 ft.

28 ft.

0-20

14

12

12

10

10

8

8

8

20-35

12

10

8

8

6

6

6

4

35-50

10

8

8

6

6

4

4

4

50-65

8

8

6

4

4

4

4

2

65-85

6

6

4

4

2

2

2

0

85-105

6

6

4

2

2

2

2

0

105-125

4

4

4

2

2

0

0

0

125-150

2

2

2

2

0

0

0

00