Power Cable Calculation
(Total RMS power output into 4Ω) x 2 = (Total input wattage [Watts])
(Total input wattage)
= (Maximum input current [Amps])
(Supply Voltage)
Example: Amplifier with a rating of 100 watts per channel into 4Ω 200 x 2 = 400 Watts (Total input power)
400 Watts / 12.5 Volts = 32 amps (Total maximum draw) Use this value of current draw to determine wire size from the chart below.
Power Wire Chart
Minimum Gauge wire
Draw | Up to | 4 to | 7 to | 10 to | 13 to | 16 to | 19 to | 22 to |
(Amps) | 4 ft. | 7ft. | 10ft. | 13 ft. | 16 ft. | 19 ft. | 22 ft. | 28 ft. |
14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | |
12 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | |
10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 | |
8 | 8 | 6 | 4 | 4 | 4 | 4 | 2 | |
6 | 6 | 4 | 4 | 2 | 2 | 2 | 0 | |
6 | 6 | 4 | 2 | 2 | 2 | 2 | 0 | |
4 | 4 | 4 | 2 | 2 | 0 | 0 | 0 | |
2 | 2 | 2 | 2 | 0 | 0 | 0 | 00 |
KX100.2 & KX200.4 Technical Manual
Version 2.0
Page 18