4. Installation Instructions

6. KN-COB-DP-LS Operating Characteristics

How to Install Your Alarm

Direct Plug Alarm

To install:

1.Choose a standard 120V unswitched outlet to plug the alarm into.

2.If outlet is mounted sideways (horizontally), rotate the plug and plug the alarm in.

CAUTION: Do not rotate the alarm while it is plugged into an outlet, as damage to plug may result.

Important Labels Provided

90º ROTATING DIRECT

PLUG

Within a few minutes, your carbon monoxide alarm will start monitoring for CO and will continue to do so as long as it receives power.

When the Model KN-COB-DP-LS CO alarm loses power: If you have a good 9V battery installed, the alarm will automatically switch to the battery back- up mode and the green LED will flash approximately every 10 seconds. The unit will continue to operate normally and detect CO for at least 20 hours.

When the Model KN-COB-DP-LS CO alarm loses power: If you have a good 9V battery installed, the alarm will automatically switch to the battery backup mode and the green LED will flash approximately every 10 seconds. The unit will continue to operate normally and detect CO for at least 20 hours.

If the battery is low or missing, or if the unit malfunctions, it will alarm dif- ferently to alert you of specific conditions. Please familiarize yourself, and other family members, of the difference between a CO alarm and an indica-

Two labels have been provided that have important information on what to do in case of an alarm. Add the phone number of your emergency service provider in the space provided. Place one label next to the alarm after it is mounted, and one label near a fresh air source such as a door or window.

5. Alarm Characteristics

Carbon Monoxide Alarm Indicator

When the alarm senses a dangerous level of CO, the unit will emit a loud alarm pattern. The alarm pattern is 4 quick beeps followed by 5 seconds of silence. This cycle repeats as long as a dangerous CO condi- tions exist. The red Alarm LED will flash the same pattern (and the PPM will be displayed on alarms with digital displays).

WARNING: When powered by battery backup only; after four minutes, the alarm will sound and flash only once every minute, until the alarm is reset or the CO is eliminated.

If the unit is unplugged it will produce a constant tone until the battery is removed or the unit is plugged back into the wall unless the Tamper- Resist feature has been deactivated or disabled.

WARNING: If at any time you test the alarm and it does not perform as described, have it replaced immediately.

6. KN-COB-DP-LS Operating Characteristics

When you first power up the alarm: The red Alarm LED will light and the alarm will sound briefly, then the green Operate LED will light. This indicates that the CO alarm is receiving power and that the alarm circuit is functioning.

tion signifying a problem with the unit.

When AC power is restored, the alarm will automatically switch back to nor- mal operating mode and the green LED will come on continuously. Observe the CO alarm regularly to make sure the green Operate LED is on, indicating normal operation. If the green Operate LED is not on, unplug the CO alarm, then plug it in again. This will clear the alarm for restart. If the green oper- ate LED does not light, your CO alarm may be malfunctioning.

The following table describes the audible alarm patterns and the recom- mended actions to take.

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound

Unit Status

Recommendation

Normal

Green LED

None

Normal AC

None

Operation

constantly on

 

operation (sensing no

 

 

 

 

CO) and with a good

 

 

 

 

battery

 

Normal

Green LED flashes

None

Normal DC operation

Verify AC power is

Operation

every 7 seconds

 

on 9V battery backup

restored as soon as

 

 

 

 

 

possible to conserve

 

 

 

 

 

battery. Replace battery.

Carbon

Red LED flashes with

4 quick beeps,

Alarm condition.

Refer to “What to do

monoxide

beeps.

5 seconds silence,

Dangerous

When the Alarm Sounds”

alarm

 

repeating

concentrations of CO

(inside front cover)

 

 

 

detected

 

Low

Red LED flashes every

One quick beep

AC powered and low

Install or replace 9V bat-

battery

15 seconds

every 15 seconds

or missing battery

tery.

 

 

 

 

 

 

Error/ serv-

Red LED flashes every

One quick beep

Unit is in error condition

Replace battery.

ice alarm

30 seconds

every 30 seconds

 

 

If “Err” continues, unit

 

 

 

 

 

has malfunctioned.

Error

Red LED

Constant alarm

Very low battery or unit

Replace immediately. Unit

 

constantly on

 

malfunction

will not respond CO

 

 

 

Normal

Red LED flashes with

4 quick beeps,

Normal operation when

CO not detected. Alarm

Test/Reset

beeps. Green and

5 seconds silence,

Test/Reset button is

for test purposes only

function

amber LED’s on

repeated once

pressed

 

Page 7
Image 7
Kidde KN-COB-DP-LS, KN-COP-DP-LS manual Alarm Characteristics, How to Install Your Alarm Direct Plug Alarm To install

KN-COB-DP-LS, KN-COP-DP-LS specifications

The Kidde KN-COP-DP-LS and KN-COB-DP-LS are advanced carbon monoxide (CO) detectors designed to enhance safety within homes and living spaces. These models feature a host of technologies and characteristics that ensure efficient monitoring and detection of carbon monoxide, a colorless, odorless gas that can pose serious health risks.

One of the standout features of both models is their digital display, which provides real-time readings of CO levels in parts per million (PPM). This feature allows users to quickly evaluate the air quality in their environment. The easy-to-read display is complemented by a battery backup option, ensuring that the detector remains operational even during power outages.

Both detectors utilize a sophisticated electrochemical sensor that is designed to respond quickly to the presence of carbon monoxide. This technology is known for its accuracy and reliability, making it a valuable addition to any home safety system. The detectors are capable of detecting low levels of CO and are programmed to trigger alarms at different thresholds, thus providing early warning to occupants.

In terms of design, the KN-COP-DP-LS and KN-COB-DP-LS are compact and unobtrusive, making them easy to install in various locations around the home, such as hallways, bedrooms, and near fuel-burning appliances. Their sleek profile ensures that they can blend in with existing home decor while still remaining functional.

Another significant characteristic of these models is their built-in test/reset button, which allows users to easily check the functionality of the unit at any time. This feature promotes regular maintenance and ensures that the detector is working correctly. Furthermore, both models offer a loud alarm that sounds at 85 decibels, alerting occupants of dangerous CO levels promptly.

In addition to detecting carbon monoxide, the KN-COB-DP-LS model offers dual functionality by also detecting explosive gases, such as natural gas or propane. This added feature makes it a versatile choice for homeowners, providing an extra layer of protection against multiple hazards.

Both the Kidde KN-COP-DP-LS and KN-COB-DP-LS detectors exemplify innovation in safety technology. With their combination of advanced detection methods, user-friendly features, and reliability, they represent a vital investment for safeguarding health and wellbeing in residential settings.