Appendix B Cabling Guidelines | 11 |
Appendix B Cabling Guidelines
UTP Cable Wiring
"Straight-Through" Cable Wiring
Pin Number | Pin Number | ||
1 | (TRX +) | 1 | (TRX +) |
2 | (TRX | 2 | (TRX |
|
|
|
|
3 | (RCV +) | 3 | (RCV +) |
|
|
|
|
6 | (RCV | 6 | (RCV |
|
| ||
4, 5, 7, 8 | Not Used | ||
|
|
|
|
Crossover”
Cable Wiring
Pin Number | Pin Number | ||
1 | (TRX +) | 3 | (RCV +) |
2 | (TRX | 6 | (RCV |
|
|
|
|
3 | (RCV +) | 1 | (TRX +) |
|
|
|
|
6 | (RCV | 2 | (TRX |
|
| ||
4, 5, 7, 8 | Not Used | ||
|
|
|
|
Table | Table |
Cable Wiring Standards
There are two governmental agencies: the Electronic Industry Association (EIA) and the Telecommunications Industry Association (TIA), which set the standard for all cable wiring requirements for commercial buildings. For
With the advent of 100Mbit network products, it is best to use higher quality CAT 5 cables like Belden or Helix as well as CAT
Refer to the illustrations on page 12 for standard
KNExTX/WG User’s Guide - Rev. A00 | Kingston Technology Company |