(I r ! I'1
Connectdrainhoseto an air gap orwastetee usingone of the
recommendedor alternate methods.
Recommended Connection Methods
Install Air Gap Kit (Part No. 300096) (A) according to kit
instructions. If adifferent air gap is used, it should be checked to
make sure it allowsfor the same air flow.
Drain hose (B) to air gap (A) to waste tee (C)
Cutdrain cod ofdrain hose as shown (D). Do Not cut ribbed
sectionto shortendrainhose(E).
,t,
Securedrainhosetoair gapwithspring-typeclamp (F). If
spring-typeclampdoesnot fit smallersection of drainhose
connector,usea smallerclamp.Smallerclampsareavailableat
plumbingsupplystores.
Connectthe air gap to wastetee usingarubberconnector(G)*
andspring-orscrew-typodamps(H).
Thewaste tee connection MUSTbe ahead of the drain
trap (I) and 20 inches (50.8om) minimum above the
floor O).
Drain hose (K) to air gap (L) to disposer (M)
Knock out disposer inlet plug (N) from inlet. Ifinletplug
fallsinsidedisposer,youmust removeinletplug before
connectingdrainhose.Ifdisposeris already installedinsink,
youmay need to removedisposerfromsink to removeplug.
DONOTcutendof drainhose.
Securedrainhose to air gap withspring-typeclamp(0).
Connectthe airgapto disposer using a rubberconnector (P)*
andspring-or serew-typoclamps(Q).
Mostdisposershave7/8"connectors,orspecia]connectorsare
availableatplumbingsupplystores.
The disposer connection MUSTbe ahead of the drain
trap (It) and 20 inches (50.8cm) minimum above the
floor (S).