Built-In Outdoor Grill Installation

(non-combustible construction)

Built-In ArchitectTM Series Outdoor Grill

Make gas connections

WARNING

Fire Hazard

Do not use grill near combustible materials. Do not store combustible materials near grill. Doing so can result in death or fire.

IMPORTANT: If grill is to be installed in a combustible enclosure, return this unit and replace it with the model which is manufac- tured for use in a combustible enclosure.

WARNING

Fire Hazard

Do not install this grill on or near combustible materials.

Doing so can result in death or fire.

WARNING

1.Place grill into outdoor enclosure, but leave enough room in back to connect to gas supply.

WARNING

Explosion Hazard

Use a new CSA International approved “outdoor” gas supply line.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

NOTE: If grill has been converted to L.P. gas, follow instructions in “If Converted to L.P. Gas” at the end of this section.

2.Natural gas connection only.

A combination of pipe fittings must be used to connect the grill to the existing gas line.

If local codes permit, use an outdoor flexible stainless steel tubing gas connector, design-certified by CSA International, to connect the grill to the rigid gas supply line. 5/8diameter line is recommended. Using a wrench to tighten, connect the gas supply to the grill. Use pipe joint compound on all non-flared male threads. Do not kink or damage the flexible connector when moving the grill.

Pipe-joint compounds suitable for use with L.P. gas must be used. Do not use Teflon® tape.

Excessive Weight Hazard

Use two or more people to move and install grill. Failure to do so can result in back or other injury.

Natural Gas Use

This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1 -latest edition, or CAN/CGA-B149.1 Natural Gas and Propane installation code.

rear of grill

flexible gas connector

1/2grill

gas pipe

3. Open shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.

valve open

valve closed

® Teflon is a registered trademark of E.I. Du Pont de Nemours and Company. 11

Page 11
Image 11
KitchenAid KFGR271SSS Built-In Outdoor Grill Installation, Built-In ArchitectTM Series Outdoor Grill, Natural Gas Use