The appliance and Its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of % psig.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than %
psig.
This unit may be used on natural or LP gas. A basic adjustment has been made at the factory for natural
gas.
WHEN USED WITH LP GASES: MAKE CERTAIN THAT PRESSURE REGULATOR HAS BEEN
CONVERTED FOR USE WITH LP GAS. ADJUST BURNER INPUT BY TURNING OUTER ORlFtCE
HOODS DOWN UNTIL SNUG AGAINST INNER ORIFICE NEEDLE.
Final adjustment of the air-gas mixture is made by turning the air shutter until a concise blue cone has
been obtained. If the flames lift from the burner, reduce the air opening in the shutter. If the flames are
yellow, increase the air shutter opening.
DOOR ADJUSTMENT CHECK
NEWSPAPER STRIPS
TOP OF DOOR
NEWSPAPER STRIPS
SIDE OF DOOR
NEFI;K *
SIDE OF
DOOR
ADJUST IN
OR OUT FOR I
, PROPER DOOF
SEAL-
NEWSPAPER STRIPS -v
BOTTOM OF DOOR
Place2’x 18”stripsofnewspaperin locarlons
indicated by illustration. Allow one end of the
paper to extend into the oven caviry. Pull
gently at each piece of paper. If door IS
properly adjusted. each piece of paper will
offer firm resistancewhen pulled. When door
~sourof adjustment. slide unitout farenough
IO expose hinges on each side (see preced-
ing page). Loosen screws and move bottom
of door to a proper fit. After completing ad-
justment tighten all screws in hinges.
ADJUST UP OR DOWN‘V
TO ALIGN DOOR
Note: If the oven is installed on a solid bottom, the gas supply must be disconnected before the oven can be slid
forward to adjust doors.